5.

TO ORDER AND REPLACE JAwS

Part Number
2299001580
5.1
Battery Clamp Jaw Replacement
Secure clamp in open position using a vise or equivalent clamping
device. IMPORTANT: Make sure the rotary switch on the front panel is in
the O (OFF) position and the jump starter is not plugged into a 110V AC
electrical wall outlet.
Unscrew fastener securing the cables to the rear of the top jaw.
Unscrew fasteners (2) securing the Copper Jaws to the plastic clamp.
Remove the jaws and braided cable.
Reverse for assembly.
6.

STORAgE AND MAINTENANCE

IMPORTANT:
CHARgE IMMEDIATELY AfTER PURCHASE
KEEP fULLY CHARgED.
Charge the internal battery immediately upon purchase, every 30 days
and after every use.
All batteries are affected by temperature. The ideal storage temperature is
at 70 degrees Fahrenheit. The internal battery will gradually self-discharge
(lose power) over time, especially in warm environments. Leaving the
battery in a discharged state may result in permanent battery damage. To
ensure satisfactory performance and avoid permanent damage, charge
the internal battery every month.
When the jump starter is ON, the clamps are live and will produce arcing
or sparking if they come in contact with each other. To prevent accidental
arcing, always keep the clamps on the storage holders and the JUMP
START ON/OFF switch in the OFF position when not using it to jump start
a vehicle.
Description
Kit, Battery Clamp Rebuild
4
QTY Per Clamp
1