AlphaESS SMILE-G3-EVCT11 Panduan Pemasangan, Pengoperasian & Pemeliharaan - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Pemasangan, Pengoperasian & Pemeliharaan untuk Pengisi Daya Baterai AlphaESS SMILE-G3-EVCT11. AlphaESS SMILE-G3-EVCT11 14 halaman.

SYSTEM CONFIGURATION AND OPERATION
4.2.4.4 Specific Power Charge Mode
1
I
I
A
AC
DC
DC
2
Loads
B
PV Panels
ESS
PV supply
Priority: 1. EV charger & Other Loads 2. Batteries of ESS 3. Feed-in
EV source
Priority: A. PV B. Batteries of ESS C.Grid
Battery supply
Priority: I. EV Charger & Other Loads
The EV charger will charge the electric vehicle with specified power. The PV and ESS
system will supply the EV charger first. If the power is not enough, the grid will supply the
EV charger simultaneously.
This specified power value can be set by yourself within a range of 6A to 16A per phase,
and the default value is the AC rated current value (16A per phase).
If PV power is available, it will prioritize supplying the EV charger and other loads, and
then charge the battery of ESS. Any excess power will be fed back into the grid.
17
3
1
C
Grid
EV Charger
18
4.2.4.5 Mode Option Suggestion
AC Output Power from
AlphaESS Energy Storage
System & PV Inverter
On-Board Charger of Vehicle
Green Charge-Slow
Green Charge-Normal
Green Charge-Quick
Max. Power Charge
Please refer to the actual situation of the customer's home loads.
4.2.5 Smart Mode Function
Smart Mode is available when the charging mode is "Green Charge" mode and OBC is
three-phase.
When the "Smart mode" is enabled:
If the real setting power is less than the minimum allowable power of three-phase, the
phase of OBC will change to single-phase.
Once the real setting power is more than the minimum allowable power of three-phase,
the phase of OBC will switch back to three-phase.

4.3 Start and Stop Charging

There are three ways to Start and Stop Charging.
1. Click the "start" or "stop" button on AlphaCloud or the App.
2. Swipe the RFID card.
3. Plug and play when the "Plug and play" strategy is enabled.
SYSTEM CONFIGURATION AND OPERATION
<5kWp
5~10kWp
>10kWp
Single
Three
Single
Three
Single
Phase
Phase
Phase
Phase
Phase
Three
Phase