In order for backlight and to power an electrical lock, a 12VDC/1A power supply is required.
Refer to the figure below, point 11. The doorphone can be also PoE powered according to
IEEE802.3af norm. A low consumption el. lock (max. 220mA) can be used with PoE.
There are two options to control external devices e.g. Lock, Light, Bell. Either NO (Normally
Open) or NC (Normally Closed). Refer to the figure below, points 9 and 10.
Point 5, DIP switch 2, normally in down position. If you move it up, the doorphone goes to a
rescue mode, default IP 192.168.1.250, access via a web browser with user name: admin,
password: 1234. Always disconnect the ETH port and the power supply before going to the
rescue mode or before going to normal mode (i.e. DIP switch 2 up or down). DIP switch 1 is
for service purposes only, do not use it.