Cres Cor Tri-Powered Series Panduan Petunjuk Pengoperasian dan Pemeliharaan - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian dan Pemeliharaan untuk Penghangat Makanan Cres Cor Tri-Powered Series. Cres Cor Tri-Powered Series 12 halaman. Hot cabinets
Holding Cabinet
Rev. 4 (10/13)
Page 4 of 12
HC-UA-11 FOR PROPANE CYLINDER INSTALLATION:
WARNING
1 . Only use a 1 lb . standard cylinder marked "PROPANE" . A larger tank can be used with an adapter (optional
accessory part number 0904-026-K See installation FL-2362) .
2 . The cylinder must be constructed and marked in accordance with the specifications for propane cylinders of the
U .S . Department of Transportation (DOT) or CAN/CSA B339 .
3 . The Cylinder should not be allowed to remain in a high heat area, such as a car, truck or direct sunlight . DO NOT
store at temperatures above 120°F (49° C) and in unauthorized storage areas not intended for cylinder storage.
4 . Hold and use the cylinder in an upright position and only use when temperatures are above 10°F (-12° C). Do not
attach near flames, pilot lights or sparks.
5 . Propane Tank Hook-up:
a . Make sure the cabinet switch is in the "OFF" position .
b . Uncap the cylinder, hold upright and insert it in the right rear compartment of the cabinet . Hand screw and
tighten the cylinder to the gas regulator . DO NOT over-tighten.
Check for leaks at the connection: Spray soapy water onto the connection and look for bubbles . Tighten more if
needed .
6 . Disconnect the cylinder when not in use . Replace the cylinder cap when storing .
HC-UA-11-NG FOR NATURAL GAS INSTALLATION ONLY:
1 . Installation shall be made with a connector that complies with Standards for Natural Gas Connection on
Movable Appliances ANSI/Z21.69b/CSA 6.166-2006.
CAUTION
2 . The cabinet and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of the system at pressures exceeding 1/12 psig (3 .45 kPA) . During pressure testing
of the gas supply piping system at pressures equal to or less than 1/2 psig (3 .45 kPA), the cabinet must be
isolated by closing the manual shutoff valve.
3 . Check for leaks at the connection: Spray soapy water onto the connection and look for bubbles . Tighten more if
needed .
FL-2361
INSTALLATION INSTRUCTIONS
This cabinet is not intended for use with natural gas.
It is not user-convertible to natural gas.
Adequate means to limit the movement of the cabinet without
depending on the connector, quick connect or associated piping
must be provided by the installer.
5925 Heisley Road • Mentor, OH 44060-1833