FIBARO Dimmer 2 Panduan Memulai Cepat - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Dimmer FIBARO Dimmer 2. FIBARO Dimmer 2 14 halaman.

FIBARO Dimmer 2 Panduan Memulai Cepat
2021. 04. 16.
Setting
0
1
Parameter 32: On/Off mode
This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced
auto-calibration will set this parameter-value to 2
Size: 1 Byte, Default Value: 2
Setting
0
1
2
Parameter 33: Dimmability of the load
This parameter contains an information about possibility of dimming the load detected during calibration procedure. (read oly)
Size: 1 Byte, Default Value: 0
Setting
0
0
Parameter 34: Soft-Start functionality
Time required to warm up the filament of halogen bulb.
Size: 1 Byte, Default Value: 1
Setting
0
1
2
Parameter 35: Auto-calibration after power on
This parameter determines the trigger of auto-calibration procedure,e.g. power on, load error, etc.
Size: 1 Byte, Default Value: 1
Setting
0
1
2
3
Parameter 37: Behaviour of the Dimmer after overload or surge.
Occuring of errors related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to
turn on the load (useful in case of momentary, short failures of the power supply
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 39: Power limit - OVERLOAD
Reaching the defined value will result in turning off the load. Additionalapparent power limit of 350VA is active by default
NOTE: Parameter 39 is relevant only when parameter 58 is set to 0.
Size: 2 Byte, Default Value: 250
Setting
0
1 - 350
Parameter 40: Response to General Purpose Alarm
Size: 1 Byte, Default Value: 3
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
Description
leading edge
trailing edge
Description
on/off mode disabled (dimming is possible)
on/off mode enabled (dimming is not possible)
mode selected automatically
Description
Load recognized as dimmable
no soft-start
Description
no soft-start
short soft-start (0,1s)
long soft-start (0,5s)
Description
No auto-calibration of the load after power on
Auto-calibration performed after first power on
Auto-calibration performed after each power on
Auto-calibration performed after first power on or after each LOAD ERROR alarm
Description
device permanently disabled until re-enabling by command or external switch
three atempts to turn on the load
Description
functionality disabled
1W-350W
10/14