FIBARO Dimmer 2 Panduan Memulai Cepat - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Dimmer FIBARO Dimmer 2. FIBARO Dimmer 2 14 halaman.
2021. 04. 16.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 48: SURGE alarm report
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 49: OVERHEAT and VOLTAGE DROP alarm report
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 50: Active power reports
The parameter defines the power level change that will result in a newpower report being sent. The value is a percentage of the previous report.
Size: 1 Byte, Default Value: 10
Setting
0
1 - 100
Parameter 52: Periodic active power and energy reports
Parameter 52 defines a time period between consecutive reports.Timer is reset and counted from zero after each report.
Size: 2 Byte, Default Value: 3600
Setting
0
1 - 32767
Parameter 53: Energy reports
Energy level change which will result in sending a new energy report.
Size: 2 Byte, Default Value: 10
Setting
0
1 - 255
Parameter 54: Self-measurement
The Dimmer 2 may include active power and energy consumed byitself in reports sent to the main controller.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 58: Method of calculating the active power
This parameter defines how to calculate active power. It is useful in acase of 2-wire connection with light sources other than resistive.
NOTE: Parameter 58 is set to 0 after forced auto-calibration.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
Description
No reaction
Send and alarm frame
Description
No reaction
Send and alarm frame
Description
No reaction
Send and alarm frame
Description
power reports disabled
(1-100%) - power report threshold
Description
periodic reports disabled
(1-32767 seconds)
Description
energy reports disabled
(0,01 - 2,55 kWh) - report triggering threshold
Description
Self-measurement inactive
Self-measurement active
Description
measurement based on the standard algorithm
approximation based on the calibration data
approximation based on the control angle
12/14