Digital audio ACHAPELL AUDIO 992EG Panduan Pengguna - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Penguat Digital audio ACHAPELL AUDIO 992EG. Digital audio ACHAPELL AUDIO 992EG 11 halaman. Vacuum tube preamplifier for microphones and instruments

• OUTPUT GAIN: OUTPUT GAIN: Provides variable control over line level signal strength. Think of this
control as your source for clean gain. Typically, this control is used to establish the desired line
level after the input gain has been set but it can work interactively with the INPUT for a wide array
of tonal possibilites. The pot is placed between the last input tube and the first 12AU7 output tube
and provides all remaining amounts of gain from the input stage.
• POWER TOGGLE: Controls the on/off power and is slave
to the rear main rocker switch.

CHANNEL SPECIFIC TOGGLES

• METER: The VU meter is buffered from the audio path
using high impedance precision isolation amplifiers.
Use of a meter isolation amplifier is important for
maintaining consistent gain and eliminating IMD
regardless of the meter status (on/off). However, it is
strongly recommended that the user switch off the
meter when it becomes 'pegged', overdriven. This
prolongs the life and accuracy of the meter.
• 48V (Phantom): 48 volts are available for condenser microphones. Each 992 is calibrated to
exactly 48 volts at the input jacks at final assembly. It is important that you NOT engage the
front panel 48v toggle with microphones that do not require it: ribbon, dynamic, and tube mics.
Applying 48v from any source (not just this preamp) to some of these microphones can damage
or destroy them.
• -20dB: If needed the user can pad the microphone inputs using the -20db attenuator. This
adjustment takes place before the first input tube. This function is defeated while the Hi-Z inputs are
engaged.
• POLARITY REVERSE: Some of the more common reasons to use this would be to reduce feedback
in a live environment, enhance the stereo image of certain content or to assist in eliminating
headphone signal bleed through during a recording session.
• MUTE: Each channel is equipped with its own mute function. The LED indicates the mute function
is engaged; output signal is completely cut. However, the meter will still monitor the output level
whether mute is engaged or not (unless it too is switched off.)
LACHAPELL AUDIO MODEL 992
CREATIVE TIP:
For near transformer-less sound,
consider engaging this pad function
and compensate for the loss of gain
by increasing the input gain control.
This approach effectively minimizes
the gain coming from the Jensen
input transformer while drastically
increasing the character of the
vacuum tube (this is only possible
with the microphone path).
6