Clear the GFP UP MISMATCH Alarm
Clear the GFP UP MISMATCH Alarm
Procedure
Match the AcUPI value to the expected UPI value or set GFP_SF to active.
If the condition does not clear, log into the Technical Support Website at
index.html
HI-LASERBIAS
Default Severity: Not Alarmed (NA), Service-Affecting (SA)
Logical Object: PORT
The High Laserbias alarm occurs when the laser card has reached end of life.
Clear the HI LASERBIAS Alarm
Procedure
Replace the laser card.
If the condition does not clear, log into the Technical Support Website at
index.html
HI-RXPOWER
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: PORT
The High Receive Power alarm occurs when the optical power coming into the receive fiber is too high.
Clear the HI RXPOWER Alarm
Procedure
Step 1
Check if the correct pluggable is properly inserted.
Step 2
Check the attenuation of the input signal. See the specification details of the pluggable and set the attenuation
accordingly.
Step 3
Check if the power threshold values are set, per the recommended range. See the specification of the pluggable
and set the power threshold values accordingly.
Alarms Troubleshooting Guide for Cisco NCS 4000 Series
8
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).