Cisco ASR1006 - ASR 1006 Modular Expansion Base Panduan Pemasangan Perangkat Keras - Halaman 17
Jelajahi secara online atau unduh pdf Panduan Pemasangan Perangkat Keras untuk Titik Akses Nirkabel Cisco ASR1006 - ASR 1006 Modular Expansion Base. Cisco ASR1006 - ASR 1006 Modular Expansion Base 47 halaman. Lightweight access points
Juga untuk Cisco ASR1006 - ASR 1006 Modular Expansion Base: Panduan Penyebaran (40 halaman)
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of
a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if
you are uncertain that suitable grounding is available. Statement 1024
Warning
This unit might have more than one power supply connection. All connections must be removed to de-energize the
unit. Statement 1028
Warning
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: AC power supplies 20 A and DC power supplies 40 A. Statement 1005
Figure 12
shows the ASR1006-PWR-DC power supply.
Figure 12
Cisco ASR 1006 Router DC Power Supply (ASR1006-PWR-DC)
8
7
Fan
1
DB-25 alarm connector
2
3
Tie-wrap tab Power supply ground lugs
DC Power supply terminal and plastic cover
4
5
Earth grounding symbol
Figure 13
shows the ASR1013/06-PWR-DC power supply.
9
55
-48/-60V
40A
This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
6
5
4
DC power supply grounding lugs
6
Power supply captive screw
7
8
Power supply handle
Power supply ON/OFF (I/O) circuit breaker switch
9
10 DC power supply LEDs
10
OUTPUT INPUT INPUT
FAIL
OK
OK
ALARMS
60V
1A MAX
3
2
1
17