Sony XCU-CG160C Panduan Teknis - Halaman 29

Jelajahi secara online atau unduh pdf Panduan Teknis untuk Kamera Digital Sony XCU-CG160C. Sony XCU-CG160C 45 halaman. Digital video camera module

Sony XCU-CG160C Panduan Teknis
GPO output system diagram (example of GPO1)
Trigger signal
Exposure
Sensor output
Trigger through signal
Exposure signal
Sensor readout signal
Pulse output
Strobe control signal
User definition 0
User definition 1
User definition 2
Sensor readout (Sensor output)
When exposure finishes, this signal indicates that the image sensor is in the image output sequence. Output is available
from the GPO2/3 connectors. The sensor readout signal is asserted before the optical black (OB) and the effective pixel
area are output.
Trigger signal
Exposure signal
Sensor readout signal
(Sensor output)
Pulse output
A pulse waveform can be output from the GPO2/3 connector. Available range is 0.5 Hz to 100 kHz.
Feature
PulseDuty
1 to 500000 to 2000000 [µs]
PulseCycle
10 to 1000000 to 2000000 [µs]
StrobeActiveDelay
StrobeActiveTime
1
0
LineSource
LineInverter
Trigger latency
Parameter
1
0
29
GPO2
GPO3