Sony XCU-CG160C Technical Manual - Page 29
Browse online or download pdf Technical Manual for Digital Camera Sony XCU-CG160C. Sony XCU-CG160C 45 pages. Digital video camera module
GPO output system diagram (example of GPO1)
Trigger signal
Exposure
Sensor output
Trigger through signal
Exposure signal
Sensor readout signal
Pulse output
Strobe control signal
User definition 0
User definition 1
User definition 2
Sensor readout (Sensor output)
When exposure finishes, this signal indicates that the image sensor is in the image output sequence. Output is available
from the GPO2/3 connectors. The sensor readout signal is asserted before the optical black (OB) and the effective pixel
area are output.
Trigger signal
Exposure signal
Sensor readout signal
(Sensor output)
Pulse output
A pulse waveform can be output from the GPO2/3 connector. Available range is 0.5 Hz to 100 kHz.
Feature
PulseDuty
1 to 500000 to 2000000 [µs]
PulseCycle
10 to 1000000 to 2000000 [µs]
StrobeActiveDelay
StrobeActiveTime
1
0
LineSource
LineInverter
Trigger latency
Parameter
1
0
29
GPO2
GPO3