SENC 150
Mechanical specifications
Resolution
Grating pitch
Scale medium
Accuracy (@ 20° C) / 1000 mm
Max. traversing speed
Force required to move reading head
Operating environment
Temperature
Relative humidity
Storage environment
Temperature
Humidity
Weight w/armor
Connecting cable armored or vinyl
Max. cable length
Measuring lengths
Reference pulse interval
Voltage supply
Protection EN 60529
0.5 µm
20 µm
Light transmission reflective off of nickel coated glass
± 3µm, ± 5µm
60 m/min
<3.4 N
0° to 50° C
25 % to 95 % (non-condensing)
-20° to 70° C
20 % to 95 % (non-condensing)
Scale case:
180 g + 0.65 g/mm ML
Reading head: 60 g
Backup spar: 1 g/mm L
Cable:
vinyl: 50 g/m
armored: 140 g/m
Connector:
55 g
Length = 4 m resp. 6 m from ML 1250 mm; connector: DE-9P
≤ 9 m
50 mm – 3075 mm (1"–120")
distance coded 50 mm
DC 5.1 V ±0.1 V / <220 mA
IP 53 when mounted as per instructions
Digital
1 µm
DC 5.1 V ±0.1 V /< 180 mA

9 Specifications

5 µm
17