Cisco UCS B200 M3 Panduan Instalasi - Halaman 31

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Perangkat Keras Jaringan Cisco UCS B200 M3. Cisco UCS B200 M3 34 halaman. Blade server
Juga untuk Cisco UCS B200 M3: Catatan Instalasi dan Layanan (36 halaman), Catatan Instalasi dan Layanan (37 halaman), Manual (8 halaman), Panduan Peningkatan (21 halaman), Catatan Instalasi dan Layanan (28 halaman)

Cisco UCS B200 M3 Panduan Instalasi
Procedure
Step 1
Enable Quiet Mode in the BIOS policy of the server's Service Profile.
Step 2
Establish a direct connection to the server, either by connecting a keyboard, monitor, and mouse to the front panel using
a KVM dongle (N20-BKVM) or by other means.
Step 3
Reboot the server.
Step 4
Press F2 during reboot to enter the BIOS setup screens.
Step 5
On the Advanced tab, select Trusted Computing and press Enter.
Step 6
Set the TPM Support option to Enable.
Step 7
Press F10 to save and exit. Allow the server to finish booting.

Server Troubleshooting

For general troubleshooting information, see the see the

Server Configuration

Cisco UCS blade servers are intended to be configured and managed using Cisco UCS Manager. For details, see the Configuration
Guide for the version of Cisco UCS Manager that you are using. The configuration guides are available at the following URL:
/www.cisco.com/en/US/products/ps10281/products_installation_and_configuration_guides_list.html

Physical Specifications for the Cisco UCS B200 M3

Specification
Height
Width
Depth
Weight

Related Documentation

The documentation set for the Cisco Unified Computing System environment is described in full at:
Cisco UCS Manager B-Series Troubleshooting
Value
1.95 inches (50 mm)
8.00 inches (203 mm)
24.4 inches (620 mm)
15.0 lbs (6.8 kg)
The system weight listed here is an estimate for a fully
configured system and will vary depending on peripheral
devices installed.
Guide.
http:/
31