Server Specifications
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Cisco Virtual Interface Card (VIC) Considerations
This section describes VIC card support and special considerations for this server.
Note
Table 6: VIC Support and Considerations in This Server
VIC
Cisco VIC 1455
APIC-PCIE-C25Q-04
Note
5.8
43
If you use the Cisco Card NIC mode, you must also make a VIC Slot setting that matches where your
VIC is installed. The options are Riser1, Riser2, and Flex-LOM. See
Settings, on page 30
for more information about NIC modes.
How Many
Slots That
Supported in
Support VICs
Server
2 PCIe
PCIe 1
PCIe 2
This VIC supports 10/25-Gigabit with the following restrictions:
• All ports must have the same speed.
• Port 1 and port 2 is one pair, corresponding to eth2-1 on APIC. Port 3 and port 4 is another pair,
corresponding to eth2-2 on APIC. Only one connection is allowed for each pair. For example, you
can connect one cable to either port 1 or port 2, and you can connect another one cable to either
port 3 or port 4. Do not connect two cables on any pair.
• APIC-PCIE-IQ10GC or UCSC-PCIE-IQ10GC should always be installed in PCIE slot 1 for APIC
M4/L4.
• APIC-PCIE-IQ10GC or UCSC-PCIE-IQ10GC can use any ports or any pair of ports to connect to
a leaf node.
• From Release 4.2(5) the UCSC-PCIE-IQ10GC Intel X710 Quad Port 10GBase-T network interface
card is supported for 10GBast-T connectivity to Cisco ACI leaf nodes.
Cisco Virtual Interface Card (VIC) Considerations
Primary Slot For
Primary Slot For
Cisco UCS Manager
Cisco Card NIC
Integration
Mode
PCIe 1
PCIe 1
Cisco APIC M4/L4 Server Installation and Service Guide
NIC Mode and NIC Redundancy
Minimum Cisco
IMC Firmware
4.0(1)
37