Cisco UCS E Series Panduan Pemecahan Masalah - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Pemecahan Masalah untuk Server Cisco UCS E Series. Cisco UCS E Series 28 halaman. Ucs e series unified computing system
Juga untuk Cisco UCS E Series: Ikhtisar Produk (8 halaman), Panduan Instalasi (46 halaman)
Overview
Procedure
SUMMARY STEPS
1. Verify that the line speed value is 9600. Use the show line command to verify the line speed value:
2. If the line speed value is correct, verify that the Baud rate value is 9.6K and the terminal type is compatible.
Use the show detail command from /bios/server-management to verify the Baud rate and terminal type:
3. Verify that the Enabled option in Serial over LAN (sol) is configured as no. Use the show detail command
from /sol to verify the sol configuration:
DETAILED STEPS
Step 1
Verify that the line speed value is 9600. Use the show line command to verify the line speed value:
Example:
Router# show line
Tty Line Typ
*
0
0 CTY
1
1 AUX
2
2 TTY
131
131 TTY
Step 2
If the line speed value is correct, verify that the Baud rate value is 9.6K and the terminal type is compatible. Use the
show detail command from /bios/server-management to verify the Baud rate and terminal type:
Example:
router# ucse 2 session imc
CIMC# scope bios/server-management
CIMC /bios/server-management # show detail
Set-up parameters:
Assert NMI on PERR: Disabled
Assert NMI on SERR: Disabled
Baud rate: 9.6k
Console redirection: Serial Port A
FRB2 Enable: Enabled
Flow Control: None
OS Boot Watchdog Timer: Disabled
OS Boot Watchdog Timer Policy: Do Nothing
Power Restore Policy: Power On
Terminal type: PC-ANSI
Step 3
Verify that the Enabled option in Serial over LAN (sol) is configured as no. Use the show detail command from /sol to
verify the sol configuration:
Example:
CIMC# scope sol
CIMC /sol # show detail
Serial Over LAN:
Enabled: no
Baud Rate(bps): 9600
Tx/Rx
A Modem
Roty AccO AccI
-
-
9600/9600
-
-
9600/9600
-
-
9600/9600
Troubleshooting Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine
Host Login and CIMC Login Troubleshooting
Uses
Noise Overruns
-
-
-
9
0
-
-
-
0
0
-
-
-
0
0
Int
0/0
-
0/0
-
0/0
-
7