SETTING UP THE DETECTOR
TAMPER
ALARM
TIN TOUT TEOL AIN AOUT SPR TEST + 12V -
EOL TAMPER 2/4
EOL ALARM
J5
EOL TAMPER
J4
J5
J3
J4
1 2 3 4
1 2 3 4
2/4 MODE
MW MODULE
YELLOW LED
MW
MW SENS.
SETTING
P/N3203974
PIR
TAMPER
L P W M A
T
he dip switch selector mounted on the unit's pc
board controls the functions setting of the detector:
Switch 1 – Marked L - LED Enable
Used for setting LED Enable / Disable
**
ON Position (Up) – all LED's enabled.
OFF Position (Down) – all LED's disabled.
Note: the state of the switch "LED" does not affect the
operation of the ALARM and TROUBLE relays
Switch 2 – Marked P - PIR SENSITIVITY Setting
Used for setting the PULSE count function in order to
provide PIR sensitivity control according to the
environment.
**
ON Position (Up) - High sensitivity for stable
environments, One motion event trips the PIR.
OFF Position (Down) - Low sensitivity for harsh
environments, Two motion events trip the PIR.
Switch 3 – Marked W - PET IMMUNITY Setting
Used for setting the PET Immune function 12Kg or
25Kg, depending on the pet Weight.
**
ON Position (Up) - Immunity to an animal up to
12kg
OFF Position (Down) - Immunity to an animal up to
25kg
Note: The detector should be reset after any change
by removing and applying the 12V power supply.
EOL Connection Options
The End-Of-Line connection options are described in
the following drawings.
Set J4 JUMPER "2/4" according to connection option
Set J5 "REOL" and J3 "RAL" Jumpers according to
EOL resistors value (see fig. 3)
Option A - 4 Wire Connection with EOL
TECHNICAL SPECIFICATION
Detection Method
PIR & Microwave pulse Doppler
Detection Range
2 ~ 15m @ H=1.8 ~ 2.4m
MW Freq. - X Band
10.525GHz / 10.687GHz / 9.9 GHz
Power Input
9.6 to
16Vdc
Active:
35mA
Current Draw
Standby: 22mA
Temp Consumption
Yes
Alarm Period
2 ± 1 sec
Form C - NC&NO
Alarm Outputs
28Vdc 0.1 A with 10 Ohm
series protection resistors
Form A N.C 28Vdc 0.1 A with
AM / Trouble Output
10 Ohm series protection resistors
open when cover is removed
N.C 28Vdc 0.1 A with 10 Ohm
Tamper Switch
series protection resistors
open when cover is removed
Warm up Period
1min
Operation Temp
-10ºC ~ +50 ºC (14 ºF~122 ºF)
Dimensions
116 mm x 60mm x 37mm
Weight
105gr.
For warranty policy and conditions please refer to CROW ELECTRONIC ENGINEERING Ltd. - WARRANTY POLICY CERTIFICATE on www.thecrowgroup.com
Switch 4 – Marked M - MW SENSITIVITY Setting
Used for setting the MW functions in order to provide
MW sensitivity control according to the environment.
BLOCK
**
ON Position (Up) - Low sensitivity, for harsh
TERMINAL
environments.
OFF Position (Down) - High sensitivity, for normal
J3
EOL ALARM
operation - immediate detection.
Switch 5 – Marked A – AND/OR Mode
Used for setting the ALARM indication mode
**
ON Position (Up) – AND mode, Alarm will activate
upon PIR AND MW detection.
OFF Position (Down) – OR mode, Alarm will activate
upon PIR OR MW detection.
** Note: Marked (**) positions are the factory default
setting of the detector.
RANGE ADJUSTMENT
RED LED
ALARM
"MW" POTENTIOMETER - adjustments according to
GREEN LED
PIR
protected area range - see fig.5&6.
The potentiometer at mid-scale is equivalent to a
distance of 15m, at min-scale - 7m.
Rotate the potentiometer clockwise to increase range,
PIR SETTING
counter-clockwise to decrease range.
Dimension change according to installation
location and room size.
DIPSWITCH
"PIR" POTENTIOMETER - adjustment according to
protected area range - see fig.5&6.
Use the Potentiometer marked "PIR" to adjust the
detection sensitivity between 30% and 100%, according
to walk test in the protected area.
Rotate the potentiometer clockwise to increase range,
counter-clockwise to decrease range.
After adjusting the sensitivity perform a walk test to
verify optimum correct sensitivity in the protected area.
LED VISUAL INDICATIONS
There are three LED's on the unit's PC board to signal
various detector events
Event
Message
Initial warm-
up (60Sec.)
No Detection
Standby
PIR walk-test
detection
MW walk-test
detection
ALARM
Option B - Connecting single detector with 2 wire and EOL resistors
Option C - Connecting multiple detectors with 2 wire and EOL resistors
STANDARDS COMPLIANCE
European Council Directive 2004/108/EC
EN50130-4+A1+A2
EN301489-3
EN301489-1
EN61000-6-3
(+/- 5%)
EN50130-5
(+/- 5%)
EN50131-1
EN50131-2-4
EN50131-6
SAFETY LVD 2006/95/EC
EN60950-1 (93/68/EEC)
Security Grade 2, Environmental Class II
For more detailed instruction please refer the manuals
which you could download from the internet at:
www.thecrowgroup.com
Testing the Detector - WALK TEST
Upon installation, the unit should be thoroughly tested
to verify proper operation.
Apply 12 Vdc power to the detector, wait 2 minutes to
finish the detector warm up time. Conduct testing with
the protected area cleared of all people.
Walk test
1. Remove front cover.
2. Make sure that PIR and MW switches are in
3. Make sure that LED switch is ON.
4. Replace the front cover.
5. Start walking slowly across the detection zone.
6. Observe that the detector's LED lights whenever
7. Allow 5 sec. between each test.
8. After the walk test is completed, the LED, PIR and
NOTE: Walk tests should be conducted, at least
once a year, to confirm proper operation and
coverage of the detector
Visible Light Filter Option
Use the optional white light filter in order to improve the
detector stability to high intensity visible light.
RED
GREEN
YELLOW
2Sec
2Sec
2Se c
CROW ELECTRONIC ENGINEERING LTD.
N345
P/N 7101740 Rev C YS
positions high sensitivity.
motion is detected.
MW switches may be changed.
(1)
(2)
Remove lens, by pressing
Bend the FILTER
both lens hooks to outside and
and place in the center
pushing the lens to the front.
of lens housing
(4)
(3)
To fit lens press it into
Insert the FILTER into
the cover from the front
the two slots at lens
until "CLICK" is heard
housing corners
CROW ELECTRONIC ENGINEERING LTD.
12 Kineret St.
Airport City, 70100 Israel
Tel. +972 3 9726000
Fax. +972 3 9726001
www.thecrowgroup.com
CROW LATIN AMERICA USA INC.
7200 NW 19 st.
Suite 307
Miami FI 33126, USA
Tel. +305 513 4001
Fax. +305 513 4005
www.crowlatinamerica.com
ARROWHEAD ALARM PRODUCTS
344B, Rosedale Road
Park Farm Industrial Estate
Albany, Auckland
New Zealand
Tel. +64 9 414 0085
Fax. +64 9 414 0088
www.aap.co.nz
These instructions supersede all previous
issues in circulation prior to March 2012.