Cru Power E-1000 Manual
Jelajahi secara online atau unduh pdf Manual untuk Inverter Cru Power E-1000. Cru Power E-1000 2 halaman. Power inverter
DC to AC
Remote Control
Overtemp LED
POWER
(24V)
OVER
30
ON
TEMP
28
26
24
OVER
22
LOAD
20
OFF
ON/OFF switch
Please keep switch
in the OFF position
during installation.
Overload LED
Firstly, thank you for purchase
our product.
Please read this manual carefully before
installing or using this product.
Specification
Firstly, thank you for purchase our
product.
Please read this manual carefully
before installing or using this
product.
SPECIFICATIONS
Model No.
HT-E-1000-12 HT-E-1000-24
AC100V / AC110V
AC Output Voltage
AC120V / AC220V
AC230V / AC240V
Input low voltage
DC10.5V
0.5V
±
alarm
Input high voltage
DC15V
0.5V
±
shut-down
Input low voltage
DC10V
0.5V
±
shut-down
Output power
1000W
continuous
50Hz/60Hz
Output Frequency
Efficiency
>85﹪
AC100V~AC120V<0.6 A
No load current draw
AC220V~AC240V<1.0 A
Dimensions
340*179*82
(L×W×H)(by mm)
Net weight (by Kg/s)
3.20
Modified Sine Wave
Output wave
Regulation
±5﹪
Over Temperature
55℃ ±5℃
protection
YES
Cooling fan
Output reverse
YES
protection
Overload protection
YES
Introduction
The power inverter series are the member
of the most advanced line of mobile AC
power systems available.
This model is used in a wide range of
application including remote homes, RVs,
sailboats and powerboats. It will operate
most televisions and VTR's, personal
computers, small appliances and tools such
as drills, sanders, grinders, mixers and
blenders.
To get the most out of the power inverter,
it must be installed and used properly.
Please read the instructions in this manual
before installing and using this model.
Name and Main function
1. Front view
a. ON/OFF switch:
Leave in the OFF position during installation.
b. Over heat protection:
LED sparkles when product temperature gets
high, it wou'd shut down automatically while
temperature arrives 55±5℃.
Power inverter
Front view
INPUT
LOAD(%)
INPUT
LOAD
(100%)
SWITCH
(12V)
1100
15
1000
900
14
800
13
700
600
12
500
11
400
300
10
200
VOLT
WATT
Input Volt and
load status indicator
Power LED
Remote Control
c. Overload protection:
Orange LED lights when inverter shut down
due to overloading. Interver would re-start
twice, if failed, inverter would shut down. Please
turn inverter OFF, reduce load and turn inverter
ON to reset.
d. LED display of Romote Control:
Display battery voltage and current. Current
should be in the green zone for continuous
operation. The inverter will operate for
several minutes when the current in the yellow
zone.
e. AC outlet:
Outlet sockets available:Australia/NZ
DC21.5V
1V
±
DC30V
1V
±
DC20V
1V
±
2. Rear view:
2Hz
±
a. Ventilation window:
Do not obstruct, allow at least one inch for
airflow.
b. Battery terminals:
Connect to 12V/24V battery or other 12V/24V
power source. "+" is positive, "-" is negative.
Reverse polarity connection will blow internal
fuse and may damage inverter permanently.
c. Chassis ground lug:
Connect to earth ground or to vehicle chassis
using #8 AWG wire.
!
WARNING!!
Operation of the inverter without a proper
ground connection may result in an electrical
safety hazard.
Quick hook - up and testing
If you would like to quick hook-up the power
inverter and check its performance before
going ahead with your installation, please
follow these guideline
Unpack and inspect the power inverter,
1.
check to see that the power switch in the
OFF position.
Connect the cables to the power input
2.
terminals on the rear panel of power
inverter. The red terminal is positive (+)
and black terminal is negative (-).
Connect the cables into the terminals and
tighten the wing nut to clamp the wires
securely.
Connect the cable from the negative terminal
3.
of the inverter to the negative terminal of the
power source. Make a secure connection.
!
CAUTION!!
Loosely tightened connectors result in excessive
drop and may cause overheated wires and
melted insulation.
Before proceed further, carefully check if the
4.
terminals connect correctly.
manual
!
Reverse polarity connection will blow a fuse in
inverter and may permanently damage the
inverter. Damage caused by reverse polarity
connection is not covered by our warranty.
Connect the cable from the positive terminal
5.
of inverter to the positive terminal of the power
source. Make secure connection.
!
AC Outlet sockets
You may observe a spark when you make this
It is suitable for Australia,
New Zealand, Canada,
connection since current may flow to charge
America, Europe, Japan
and Universal type.
capacitors in the power inverter.
Do not make this connection in the presence of
flammable fumes, explosions or fire may result.
Set power inverter switch to the OFF
6.
position, the indicator lights may blink and
the internal alarm may sound momentarily.
This is normal. Plug the test load into the
AC receptacle on the front panel of the inverter.
Leave the test load switch off.
Set power inverter switch to the ON position
7.
and turn the test load on, the inverter should
supply power to the load.
North America
1. Where to install
Europe
The power inverter should be installed in a
Universal
location that meets the following requirements:
Japan
a. Dry - Do not allow water to drip or splash on
the inverter.
b. Cool - Ambient air temperature should be
between 0°C and 40°C, the cooler environment
is better.
c. Ventilated - Allow at least one inch of
clearance around the inverter for airflow.
Ensure the ventilation openings on the rear
and bottom of the unit are not obstructed.
d. Safe - Do not install the inverter in the same
compartment as batteries or in any
compartment capable of storing flammable
liquids such as gasoline.
2. Cables
DC to AC inverters requires high amperage/low
voltage DC power to low amperage/high voltage
AC power. To operate properly connect inverter
DC input terminals direct to battery with heaviest
wire available see chart below:
Max Watts Out
100W
150W
300W
600W
1000W
1200W
1500W
1800W
2500W
3. Grounding
The power inverter has a lug on the rear panel
"chassis ground". This is to connect the chassis
of the power inverter to the ground. The ground
terminals in the AC outlets on the front panel of
the inverter are also connected to the ground lug.
The chassis ground lug must be connected to a
grounding point, which will vary depending on
where the power inverter is installed. In a vehicle,
connect the chassis ground to the chassis of the
vehicle. In a boat, connect to the boat's grounding
systems. In a fixed location, connect the chassis
ground lug to earth.
HT-E-152A2
CAUTION!!
WARNING!!
Installation
Approx. Amps
Teq'dWire Gauge
10A
15A
30A
60A
#6 or 2 X #10
100A
120A
150A
180A
2 X #4
250A
2 X #4
#16
#16
#12
# 4
# 4
# 4