Cru Power E-1000 Manual - Halaman 2

Jelajahi secara online atau unduh pdf Manual untuk Inverter Cru Power E-1000. Cru Power E-1000 2 halaman. Power inverter

The neutral (common) conductor of the power
inverter AC output circuit is connected to the
chassis ground. Therefore, when the chassis is
connected to ground, the neutral conductor will
also be grounded. This conforms to national
electrical code requirements that separately
derived AC sources (such as inverters and
generators) have their neutral tied to ground in
the same way that the neutral conductor from the
utility line is tied to ground at AC breaker panel.
Caution!
The negative DC input of the power inverter is
connected to the chassis. Do not install the
power inverter in a positive ground DC system.
A positive ground DC system has the positive
terminal of the battery connected to the chassis
of the vehicle or to the grounding point.
Warning!
Do not operate the power inverter without
connecting it to ground. Electrical shock hazard
may result.
Operation
To operate the power inverter, turn it on using the
ON/OFF switch on the front panel. The power
inverter is now ready to deliver AC power to your
loads. If you are operating several loads from the
power inverter, turn them on separately after the
inverter has been turned on. This will ensure that
the power inverter does not have to deliver the
starting currents for all the loads at once.
Remote Control:
The ON/OFF switch turns the control circuit in the
power inverter on and off.
When the switch is in the OFF position, the power
inverter draws no current from battery. When the
switch is in the ON position but with no load, the
power inverter draws less than 600mA
(12V version) or 300 mA (24V version) from
battery.
1. Battery voltage indicator
The battery voltage graph indicates the voltage
at the input terminals of the power inverter. At low
input current, this voltage is very close to the
battery voltage. At high input current, this voltage
will be lower than the battery voltage because of
the voltage drop across the cable and connections.
Ideally, the voltage should remain in the green
area of the bar graph. If the voltage goes into the
red area at top and bottom of the graph, inverter
may shutdown.
2. Load percentage indicator
The load watts grap indicates the watts of the
appliances you use.
If the load goes into the red area at top, inverter
may shut down.
3. Overtemp indicator
The overtemp indicator indicates that the power
inverter has shut itself down because it is
overheated. The power inverter may overheat
because it has been operated at power levels
above its rating, or because it has been installed
in a location which does not allow it to dissipate
heat properly.
Please turn on the inverter again when it cools
down.
4. Overload indicator
The overload indicator indicates that the power
inverter has shut itself down because its output
circuit has been short circuited or drastically
overloaded.
Turn off the inverter, correct the fault condition
or reduce load, then turn on the inverter and try
again.
Operating limits
1.Input voltage
The power inverter will operate from input voltage
ranging 10V-15V (12V ver.) or 20V - 30V (24V ver.).
If the voltage drops below 10.5V (12V ver.) or
21.0V (24V ver.), an audible low battery warning
will sound and the voltage indicator will be in the
lower red zone.
The power inverter will shut down
if the input voltage drops below 10V (12V ver.) or
20V (24V ver.). This protects your battery from
being over discharged.
The power inverter will also shut down if the input
voltages exceed 15V (12V ver.) or 30V (24V ver.).
This protects the inverter against excessive input
voltage indicator will be in the upper red zone.
Although the power inverter incorporates protection
against over voltage, it may still be damaged if the
input voltage is allowed to exceed 20V (12V ver.)
or 40V (24V ver.).
※The error of above spec is ±0.5V
Troubleshooting
1.Common problems
Buzz in audio systems:
a.
Some inexpensive stereo systems and "boom
boxes" will emit a buzzing noise from their
loudspeakers when operated from the power
inverter. This is because the power supply in
the device does not adequately filter the modified
sine wave produced by the power inverter.
The only solution is to use a sound system that
incorporates a higher quality power supply.
Television interference:
b.
Operation of the power inverter can interfere with
television reception on some channels. If this
situation occurs, the following steps may help to
alleviate the problem.
-Make sure that the chassis ground lug on the
back of the power inverter is solidly connected
to the ground system of your vehicle, boat or home.
-Do not operate high power loads with the power
inverter while watching television.
-Make sure that the antenna feeding your
television provides an adequate ("snow free")
signal and that you are using good quality cable
between the antenna and the television.
-Move the television as far away from the power
inverter as possible.
-Keep the cables between the battery and the
power inverter as short as possible and twist them
together with about 2 to 3 twists per foot. This
minimizes radiated interference from the cables.
2.Troubleshooting guide
Problem
possible cause
1.Make sure that inverter
No Output voltage
cable connects to battery
well
No voltage indicator
2.Internal fuse blown out
Inverter shuts down
Overload
and overload light
shows
Inverter shuts down
and overtemp light
Overtemperature
shows
Low battery alarm
Battery volt is low
Maintenance
Very little maintenance is required to keep your
inverter operating properly. You should clean
the exterior of the unit periodically to prevent
accumulation of dust and dirt. At the same time,
tighten the screws on the DC input terminals.
Warranty
We offer 12 monts warranty from the date of
purchase and will repair or replace any defective
power Inverter, this limited warranty is void if the
unit is abused, modified, installed improperly, if the
housing has been removed, if the serial number is
missing, or if the original identification markings
have been defaced, altered, or removed. The
supplier is not liable for any incidental,
consequential or other damages arising from the
use, cost of removal, installation, or troubleshooting
of thw customer's electrical systems.
This is only warranty and the company makes
no other warranties, express or implied, including
warranties of merchantability and fitness for a
particular purpose.
Repair or replacement are your sole remedies
and shall not be liable for damages, whether
direct, incidental, special or consequential, even
though cause by negligence or other fault.
Rear view
Battery terminals
Connect to battery or
other power source.
"+" is positive(Red),
-
"
" is negative(Black).
Reverse polarity connection
will blow internal fuse and
may damage inverter
permanently.
solution
1.Re-set the cable
2.Change new fuse
Reduce load
Improve ventilation
reduce inverter
temperature
or let it cool down
naturally
Charge battery
Ventilation
window