Aeon Labs AEO HEM2-100A Panduan Memulai Cepat - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Alat Ukur Aeon Labs AEO HEM2-100A. Aeon Labs AEO HEM2-100A 11 halaman. Z-wave clamp power meter 2nd generation - two clamps max. 100 ampere
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators
5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.
There are two different role a controller can have. There is always one single primary controller that is managing the
network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other
controllers don't manage the network itself but can control other devices. They are called secondary controllers. The
image also shows that its not possible to operate a sensor just from a remote control. Sensors only communicate with
static controllers.
Product description
The Aeon Labs Smart Energy Monitor is a low-cost energy monitor for the entire home. It can wirelessly
report immediate wattage and kWh usage to central control point gateways and can be easily installed.
Installed in an electricity box, the energy meter will monitor the total consumption of electricity used by an
entire building. And its intelligent clamps will report that energy use back to your control point, in watts or
kilowatt-hours, and in real time. So you can see how much electricity you really use and when you use it.
The main body is anchored using a back mount. The device is powered from a normal AC power supply.
The device has two clamps and reports W and kWH (up to 100 Ampere).
Before Device is installed
Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure
an error-free functioning.
ATTENTION: only authorized technicians under consideration of the country-specific installation
guidelines/norms may do works with 230?Volt mains power. Prior to the assembly of the product, the
voltage network has to be switched off and ensured against re-switching.
The product is permitted only for proper use as specified in the user manual. Any kind of guarantee claim
has to be forfeited if changes, modifications or painting are undertaken. The product must be checked for
damages immediately after unpacking. In the case of damages, the product must not be operated in any
case. If a danger-free operation of the equipment cannot be assured, the voltage supply has to be
interrupted immediately and the equipment has to be protected from unintended operation.
Installation Guidelines
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 2