Dinel CLS-23 Buku Petunjuk - Halaman 4

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Aksesori Dinel CLS-23. Dinel CLS-23 18 halaman. Capacitive level sesors
Juga untuk Dinel CLS-23: Manual (20 halaman)

Dinel CLS-23 Buku Petunjuk
3 .  b
rieF
Capacitive level sensors (switches) CLS 23 are designed for limit level detection of electrically
conductive and nonconductive uids in vessels reservoirs sumps pipes tans etc. The sensitiv-
ity of the sensor can be easily set by placing magnetic pen on sensitive spot.
The process coupling at the housing can be with metric thread .  . pipe thread
   or sealing thread T . utput performances  transistor output with open
collector  two wire electronic switch  and R output.
There are net performances available N  ormal for noneplosive areas E  tended tem-
perature range for noneplosives areas Xi  plosion proof intrinsically safe for eplosive ar-
eas NT  igh temperature variant for noneplosives areas and XiT  igh temperature variant
for eplosive areas.
4 .  F
eatUres oF variants
CLS 23_ 10
CLS 23_ 11
CLS 23_ 12
CLS 23_ 20
CLS 23_ 21
CLS 23_ 30
 Dinel
CLS 23
Uncoated short bar electrode for sensing of electrically nonconductive
liuids mineral and plant oilsresins etc.. ounting in horiontal position.
lectrode length  mm.
Insulated (coated) short bar electrode for nonaggressive electrically
conductive liuid sensing water water solutions. The insulation is made
from  olypropylene.
lectrode length  mm.
Insulated (coated) short bar electrode for moderately aggressive electri
cally conductive liuid sensing chemicals water moderately aggressive
water solutions. igher temperature resistance than variant . The insula
tion is made from  Tetrauoroethyleneeruororopylene.
lectrode length  mm
Partly insulated rod electrode for level detection of conductive and non
conductive liuids partially resistant to vapours water condensation in the
sensing area. The insulation is made from . ertical mounting horiontal
mounting from the side is possible for shorter electrodes up to  mm
lectrode length from  mm to  m.
Fully insulated rod electrode for universal use for level detection of con
ductive liuids water water solutions. Resistant to vapours water conden
sation in the sensing area and partially resistant to medium
spraying. The insulation is made from . ertical mounting horiontal
mounting from the side is possible for shorter electrodes up to  mm.
lectrode length from  mm to  m.
Uncoated removable rod electrode for level detection of conductive and
nonconductive liuids. ertical mounting horiontal mounting from the
side is possible for shorter electrodes up to  mm.
lectrode length from  mm to  m.
5