Dinel CLS-23 Buku Petunjuk - Halaman 4
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Aksesori Dinel CLS-23. Dinel CLS-23 18 halaman. Capacitive level sesors
Juga untuk Dinel CLS-23: Manual (20 halaman)
3 . b
rieF
Capacitive level sensors (switches) CLS 23 are designed for limit level detection of electrically
conductive and nonconductive uids in vessels reservoirs sumps pipes tans etc. The sensitiv-
ity of the sensor can be easily set by placing magnetic pen on sensitive spot.
The process coupling at the housing can be with metric thread . . pipe thread
or sealing thread T . utput performances transistor output with open
collector two wire electronic switch and R output.
There are net performances available N ormal for noneplosive areas E tended tem-
perature range for noneplosives areas Xi plosion proof intrinsically safe for eplosive ar-
eas NT igh temperature variant for noneplosives areas and XiT igh temperature variant
for eplosive areas.
4 . F
eatUres oF variants
CLS 23_ 10
CLS 23_ 11
CLS 23_ 12
CLS 23_ 20
CLS 23_ 21
CLS 23_ 30
Dinel
CLS 23
Uncoated short bar electrode for sensing of electrically nonconductive
liuids mineral and plant oilsresins etc.. ounting in horiontal position.
lectrode length mm.
Insulated (coated) short bar electrode for nonaggressive electrically
conductive liuid sensing water water solutions. The insulation is made
from olypropylene.
lectrode length mm.
Insulated (coated) short bar electrode for moderately aggressive electri
cally conductive liuid sensing chemicals water moderately aggressive
water solutions. igher temperature resistance than variant . The insula
tion is made from Tetrauoroethyleneeruororopylene.
lectrode length mm
Partly insulated rod electrode for level detection of conductive and non
conductive liuids partially resistant to vapours water condensation in the
sensing area. The insulation is made from . ertical mounting horiontal
mounting from the side is possible for shorter electrodes up to mm
lectrode length from mm to m.
Fully insulated rod electrode for universal use for level detection of con
ductive liuids water water solutions. Resistant to vapours water conden
sation in the sensing area and partially resistant to medium
spraying. The insulation is made from . ertical mounting horiontal
mounting from the side is possible for shorter electrodes up to mm.
lectrode length from mm to m.
Uncoated removable rod electrode for level detection of conductive and
nonconductive liuids. ertical mounting horiontal mounting from the
side is possible for shorter electrodes up to mm.
lectrode length from mm to m.