Aeotec Door / Window Sensor 7 Panduan Pengguna - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Aksesori Aeotec Door / Window Sensor 7. Aeotec Door / Window Sensor 7 10 halaman.
Juga untuk Aeotec Door / Window Sensor 7: Panduan Pengguna (9 halaman), Panduan Memulai Cepat (11 halaman), Panduan Pengguna (9 halaman)
31/07/2019
#3: Digital Input
#4: Ground
Digital + Ground is used to connect an external dry contact mechanism to control scenes.
Push button
Water sensor probes
External magnet detection
etc.
Note: Please note that the contact Digital Input (#3) and Ground (#4) is a normally open (NO) contact. Closing the
contact sends out a command (Open or Close). You must use a NO dry contact device with these terminals.
Door
/
Window
Sensor
7
as
Dry
Contact
Sensor.
Using configuration commands the source of "open" and "close" events can be chosen between the internal magnet
detector or external dry contact connected on terminal #3 and #4.
You can find direct information in this article here:
https://aeotec.freshdesk.com/support/solutions/articles/6000223859
(https://aeotec.freshdesk.com/support/solutions/articles/6000223859)
Scene Controller.
When activated by configuration parameter #13 the device can perform as a scene controller. The external dry contact
will then act as a scene controller with a total of 7 scenes that can be activated:
1. Contact Pressed 1 time
2. Contact Pressed 2 time
3. Contact Pressed 3 time
4. Contact Pressed 4 time
5. Contact Pressed 5 time
6. Contact held down
7. Contact released
You can find out more information on how to use Door / Window Sensor 7 in this article here:
https://aeotec.freshdesk.com/support/solutions/articles/6000223885
(https://aeotec.freshdesk.com/support/solutions/articles/6000223885)
Communication
test.
This utilizes the Power Level command class to determine the health between the Door / Window Sensor 7 and your
Z-Wave gateway. This will tell you if the Door / Window Sensor 7 has a healthy connection to your system and is a
great method of debugging connectivity issues.
1. Set Parameter #4 to value #1
2. Double click the Tamper Switch.
3. Result:
Blinks
once
- success
Blinks
5x
times
- failure
https://aeotec.freshdesk.com/support/solutions/articles/6000218764-door-windows-sensor-7-user-guide
Door / Window 7 user guide : Aeotec Group