19/11/2020
Outdoor installation.
Please note that when installed outdoors of your home, your TriSensor should only be relied on for temperature and light where as the motion sensing
capabilities should be disabled on your gateway in order to avoid false motion readings. If selecting an outdoor location, it s important to position your
TriSensor in a sheltered location. It is best if your TriSensor is not directly exposed to rain, snow, or other elements.
If you wish to use TriSensor outdoors, you will need to lower settings, and angle TriSensor accordingly as all environments will require different solutions
or different settings for the motion sensor to work properly. Parameter 3 [1 byte] will determine the sensitivity of the motion sensor from a value range of 0
disabled to 11 max sensitivity (your ability to configure this setting will depend on the gateway used).
It is advised that if you are seeing false motion tracking, run trial and error to determine the best sensitivity from a range of 0 - 11 by going down 1 sensitivity
level after every test (first 5, 4, 3, 2, then 1), while setting Parameter 3 [2 byte] to 5 to allow a PIR sensor timeout of 5 seconds after detecting motion to
rapidly determine the best settings for motion use outdoors.
Reset to factory default
Inclusion
Exclusion
NIF
Wakeup
Protection
FirmwareUpdate
SetAssociation

Association Groups:

Group Number
1
2
3

Configuration Parameters

Parameter 1: Motion Retrigger Time
This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter.
Size: 2 Byte, Default Value: 30
Setting
0
1 - 32767
Parameter 2: Motion Clear Time
This parameter is configured the time to clear motion event after a motion event detected. Time to motion clear, the device will send a clear event report to
controller and send BASIC_SET= 0x00 to nodes associated in group 2.
Size: 2 Byte, Default Value: 240
Setting
1 - 32767
Parameter 3: Motion Sensitivity
This parameter is configured the sensitivity that motion detect. 0PIR sensor disabled.
Size: 1 Byte, Default Value: 11
Setting
0
1 - 11
Parameter 4: Binary Sensor Report Enable
Size: 1 Byte, Default Value: 0
manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini
manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini
1. Power up the device.
2. Press and hold the button for 15s until Red Led is blinking,then release the button
1. Open the battery compartment.
2. Press the button once.
1. Open the battery compartment.
2. Press the button once.
XXXNIF
Press and hold the button at least 2s until Red Led is on and then release the button,device will send
wakeup notification to controller if device is in a Z-Wave network.
XXXProtection
XXXFirmwareUpdate
XXXSetAssociation
Maximum
Description
Nodes
5
Lifeline
5
Controlling group, all nodes associated in this group will be controlled through BASIC_SET
command by the device when device detects a movement event. Basic Set Value is decided
by Configuration Parameter 6.
5
Controlling group, all nodes associated in this group will be controlled through BASIC_SET
command by the device when device detects an ambient temperature alarm (Decided by
Configuration Parameter 7).
Description
Will disable PIR sensor from triggering until motion timeout has finished.
Time in seconds
Description
Second
Description
Disable
Sensitivity.
3/7