Ariston 60 cm Panduan Servis - Halaman 30
Jelajahi secara online atau unduh pdf Panduan Servis untuk Kulkas Ariston 60 cm. Ariston 60 cm 47 halaman.
FAULT
CAUSE
FRIDGE Evaporator NTC probe
F23
open / short-circuit
FREEZER Air NTC probe open /
F24
short-circuit
FREEZER Evaporator NTC probe
F25
open / short-circuit
CCZ Air NTC probe open / short-
F26
circuit
F28
Display PCB does not work
F40
"ON/OFF " button does not work
F41
"I Care" button does not work
F42
"Holiday" button does not work
F43
"ICE PARTY" button
"Ever Fresh" button
F44
F45
"Super Freeze" button
F46
"Super Cool" button
F47
"Alarm" button
F49
FRIDGE "+" button
F50
FRIDGE "-" button
CCZ button
F51
F52
FREEZER "+" button
F53
FREEZER "-" button
Service Manual
NEW ARISTON 60 cm PLATFORM
CORRECTIVE ACTIONS
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 5 and 6 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J12 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
Edition
2006.06.15
E
Language
English
N
30