Whirlpool CGM2751KQ Panduan Petunjuk Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Pengering Whirlpool CGM2751KQ. Whirlpool CGM2751KQ 27 halaman. Commercial gas and electric dryer 120/240-volt, 60 hz

The console
houses the accumulator
timer with actuating
arm and bufton,
The timer is set to provide
45 minutes
(4 pins) of drying time when activated
by the coin slide, Timer cams for
30- minute (6 pins) and 60-minute
(3 pins) drying times are included
in
the parts bag,
The coin-slide
mechanism,
control
panel
lock and key, and coin-box
lock
and key are not included
and are
available
from usual industry sources,
To change to a
30- or 60-minute
timingcam
Electrical Shock Hazard
Disconnect power before
making cam changes.
Failure to do so can result in
death or electrical shock,
Each coin-operated
dryer is
equipped
with a 45-minute
timer
cam that provides
45 minutes of
drying time when activated
by the
coin slide,
You can install the 30-minute
or
60-minute
timing cam (shipped
with
dryer) as follows:
1. Unlock meter case, Reach
into
control
panel
area,
2. Turn the timing cam by hand until
the "V" -shaped
notch
lines up
below the ratchet
tooth,
ratchet tooth
timing cam
drive
Line u
lug
clear
ratchet
hub
tooth,
down
3. Insert a narrow, flat-blade
screwdriver
under the timing cam
near the clock shaft, Gently lift cam
straight
up and off shaft making
sure that the "V" -shaped
notch
clears the ratchet
tooth,
4. Place new cam (hub side down)
over clock shaft, Line up flat side of
shaft with flat side of cam hole,
Check that drive lug is in place,
5. Turn cam until "V" -shaped
notch
lines up with ratchet
tooth,
6. Press cam down in place
on motor
shaft, Make sure that "V" -shaped
notch
clears the ratchet
tooth,
7. Close and lock the meter case,
Exhaust
requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in
death or fire.
Do not use non-metal
flexible vent,
metal vent that is smaller than four
inches in diameter
or exhaust
hoods with
magnetic
latches,
The dryer must be exhausted
outdoors.
Do not exhaust
dryer into a gas vent,
chimney,
wall, ceiling,
or concealed
space
of a building,
Do not install flexible vent in enclosed
walls, ceilings or floors,
If using an existing exhaust system, clean
lint from entire length of exhaust system,
Make sure exhaust hood is not plugged
with lint,
The exhaust system should be inspected
and cleaned
yearly,
Replace
any plastic or metal foil exhaust
vent with rigid metal or flexible
metal
vent,
Use 4" (10,2 cm) vent clamps to
secure vent system,
exhaust airflow
beffer
[==] good
_=]
Four-inch (1 0.2 cm) metal exhaust vent
isrequired, Plan installation to use the
fewest
number
of elbows and turns,
Metal flexible vent must be fully
extended
and supported
when the
dryer is in its final position,
DO NOT
KINK OR CRUSH THE VENT, The metal
flexible vent must be completely
open to allow adequate
exhaust air
to flow.
Allow as much
room as possible
when using elbows or making
turns,
Bend vent gradually
to avoid
kinking,
Remove excess flexible vent to avoid
sagging
and kinking that may result in
reduced
air flow,
Exhaust outlet is located
at the
center
of the boftom
dryer back,
The exhaust vent can be routed
up,
down,
left, right, behind
the dryer or
straight
out the back of the dryer,
Maximum
length of exhaust system
depends
upon the type of vent used,
number
of elbows and type of
exhaust
hood, The maximum
length
for both rigid and flexible vent is
shown in the chart,
EXHAUSTHOOD TYPE
r
r
(10.2cnQ
10.2cm)
of 900
Jums
4"
0o=cm)
MAXIMUM
LENG1HRIGIDOF
METAL4"INCH_NT10"2
_
DIA_R
0
64 FT. (19.5 m)
64 FT. (19+5m]
58 FT.(17.7 m)
I
54 FT. (16.5 m)
54 FT. (16+5m]
48 FT.(14.6 m]
2
44 FT. (13_ m)
44 FT. (13_ m]
38 FT.(II.6 m]
3
35 FT. (10.7 m)
35 FT. (10.7 m)
29 FT.(8.8 m)
4
27FT. ( 8.2m)
27FT. ( 8.2m)
21FT. (6AnO
MA)0MUM LENGIH OF 4-INCH (10.2cm) DIAMElSR
FLI_IBLE MErAL VENT
O
36Fr.(11.0 m)
36FT. ( ll.Om)
28FT. ( 8_m)
1
31Fr. ( 9.4m)
31FT. ( 9Am)
23FT. ( 7.0 m)
2
27FT. ( 8.2m)
27FT. ( 8.2 m)
19FT. ( 5.8 m)
3
25 FT.(7.6 m]
25 FT.(7.6 m)
17 FT.(5.2 m)
4
23FT. ( 7.0m]
23FT. ( 7.0 m)
15FT. ( 4,6 m)
For exhaust systems not covered
by
the exhaust
length chart, see
Whirlpool
Service Manual,
"Exhausting
Whirlpool
Dryers," Part No, 603197,
available
from your Whirlpool
parts
distributor,
If dryer is installed in a confined area,
such as a bedroom,
bathroom or
closet, it must be exhausted
to the
outside and provision
made for
enough
air for combustion
and
ventilation,
(Check
governing
codes
and ordinances,)
See "Recessed
area
and closet installation
instructions"
on
Page 12,
Page 3