Whirlpool AKR473.1/IX Panduan Kesehatan & Keselamatan, Penggunaan & Perawatan, dan Pemasangan - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Kesehatan & Keselamatan, Penggunaan & Perawatan, dan Pemasangan untuk Kap Ventilasi Whirlpool AKR473.1/IX. Whirlpool AKR473.1/IX 15 halaman.

DESCRIPTION AND USE OF HOOD
1. Control panel.
2. Grease filter.
3. Grease filter spring release handles.
4. Lighting.
5. Pull-out steam deflector.
6. Extractor unit body.
Control panel
1. Light ON/OFF button
2. Timer ON/OFF button: time-delayed switch-off of the selected extraction speed (power):
Extraction speed (power) 1: 20 minutes
Extraction speed (power) 2: 15 minutes
Extraction speed (power) 3: 10 minutes
Intensive extraction speed (power): 5 minutes.
3. OFF / Extraction speed (power) decrease button
4. ON / Extraction speed (power) increase button
5. Display, shows:
a. Extraction speed (power): LEDs L1 - L2 - L3 - L4 (flashing) light up according to the selected
extraction speed (power).
Note: LED L4 - intensive extraction speed (power) works for approximately 5 minutes after which
the hood sets the intermediate speed.
b. Timer: The LED of the selected speed will flash to indicate that the timer is active.
c. Grease filter saturation: LEDs L3 and L4 flash alternately with a short time interval.
d. Active carbon filter saturation: LEDs L3 and L4 flash at the same time with a short time
interval.
Filter saturation signaling reset: Carry out filter maintenance, then press and hold button 2 until
the LEDs go out.
Note: Active carbon filter saturation is normally disabled and should only be activated if the hood is
used as a filter version (with carbon filter fitted).
To do so, proceed as follows:
- switch off the hood
- press and hold both buttons 3 and 4 until LEDs L1 and L2 briefly flash.
To turn off repeat this process, only LED L1 will briefly flash.