6.3 Volumetric flow rate

FL
RE

6.4 Power

FL
RE

6.5 Reset balance

Adjust. values:
back
Reset balance
Antifr. type

6.6 antifreeze type

Adjust. values:
back
Antifr. type
Flow measurem.

6.7 antifreeze

Adjust. values
back
Antifr. type
Antifreeze
6.8 Type of flowmeter
Adjust. values:
back
Antifr. type
Flow measurem.
| 10
200 l/h
Flow
85,6 °C
45,7 °C
9.30 kW
Power
85,6 °C
45,7 °C
Water
Water
V40
Propylene
40 %
Water
V40
The volumetric flow rate is indicated (l/h or gpm).
The current power is indicated (in kW).
note:
The precision of the power indication depends on the
flowmeter used. At low flow rates, deviations from the
actual value are possible and caused by technical reasons!
All balance values will be reset to 0.
Adjustment channel for the antifreeze type used. There are
different types of heat tranfer fluid to choose from. Water
or water / glycol mixtures are used:
• water
• propylene
• ethylene
• Tyfo LS
Adjustment channel for the ratio of water / glycol ("anti-
freeze" is only visible, when the antifreeze type "propylene"
or "glycol" has been selected before).
ajdustment range: 20 % ... 70 vol. %
factory setting: 40 %
Adjustment channel for the flowmeter type which is used.
The factory setting is V40 flowmeter.
• V40
• VTP