Zanussi ZT 695 Buku Instruksi - Halaman 22

Jelajahi secara online atau unduh pdf Buku Instruksi untuk Mesin pencuci piring Zanussi ZT 695. Zanussi ZT 695 24 halaman. Zanussi instruction dishwasher zt 695

Zanussi ZT 695 Buku Instruksi
The waste connection must be at a height of between 30 cm
(minimum) and 100 cm (maximum) from the bottom of the

dishwasher.

The drain hose can face either to the right or left of the
dishwasher
Ensure the hose is not bent or squashed as this could
prevent or slow down the discharge of water.
If you use a drain hose extension it must be no longer than 2
metres and its internal diameter must be no smaller than the
diameter of the hose provided.
Likewise the internal diameter of the couplings used for
connections to the waste outlet must be no smaller than the
diameter of the hose provided.
The sink plug must not be in place when the machine is
draining as this could cause the water to siphon back into
the machine.

Electrical connection

This appliance must be earthed.
The manufacturer declines any responsibility
should this safety measure not be observed.
If the plug that is fitted to your appliance is not suitable for
the socket, it must be cut off and the appropriate plug fitted.
Important
The wires on the mains lead are coloured in accordance
with the following code:
Green and Yellow
-Earth
Blue
-Neutral
Brown
-Live
If you fit your own plug, the colours of the wires in the mains
lead of your appliance may not correspond with the
markings identifying the terminals in your plug.
Proceed as follows:
1. Connect the Green and Yellow (earth) wire to the
terminal in the plug which is marked with the letter "E" or
the earth symbol
or coloured green and yellow.
2. Connect the Blue (neutral) wire to the terminal in the
plug which is marked with the letter "N" or coloured
black.
3. Connect the Brown (live) wire to the terminal in the plug
which is marked with the letter "L" or coloured red.
The plug moulded onto the lead incorporates a 13amp
BSI362 fuse. Only ASTA or BSI fuses should be used.
The plug must not be used if the fuse cover/carrier is lost.
The cover/carrier is indicated by the coloured insert at the
base of the product.
A replacement cover/carrier must be obtained from your
local Service Force Centre.
This appliance complies with the following E.E.C.
Directives:
- 73/23 or 19.2.73 (Low Voltage Directive) and
subsequent modifications;
- 89/336 or 3.5.89 (Electromagnetic Compatibility
Directive) and subsequent modifications.
CS10
CE03
11
+ 2 m max