Zanussi ZGG35214 Panduan Pengguna - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kompor Zanussi ZGG35214. Zanussi ZGG35214 16 halaman.
Juga untuk Zanussi ZGG35214: Panduan Pengguna (28 halaman), Panduan Pengguna (16 halaman), Panduan Pengguna (20 halaman)

Zanussi ZGG35214 Panduan Pengguna
4. With a thin screwdriver, adjust the by-pass
screw position.
1
The by-pass screw
1
– If you change from natural gas G20 20
mbar to liquid gas, fully tighten the ad-
justment screw in.
– If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
Warning! Make sure the flame does not
go out when you quickly turn the knob
from the maximum position to the minimum
position.
Electrical connection
• The electrical work necessary to install the
appliance must be done by a qualified elec-
trician or competent person, according to the
current regulations.
• The appliance must be earthed.
• Always use a correctly installed shockproof
socket.
• Make sure that there is access to the mains
plug after the installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• The appliance must not be connected with
an extension cable, an adapter or a multiple
socket. There is a risk of fire. Make sure that
the ground connection complies with the
standards and regulations force.
• The power cable must not touch any hot
parts.
• The electrical installation must have an isola-
tion device which lets you disconnect the ap-
pliance from the mains at all poles. The isola-
6
tion device must have a contact opening
width of minimum 3 mm.
• You must have the correct isolation devices:
line protecting cut-outs, fuses (screw type
fuses removed from the holder), earth leak-
age trips and contactors.
• The connection cable parts must not be
heated to a temperature above 90°C.
Electrical Requirements
Permanent electrical installation must comply
with the latest I.E.E. Regulations and local Elec-
tricity Board regulations. For your own safety
the installation must be done by a qualified
electrician (e.g. your local Electricity Board, or a
contractor who is on the roll of the National In-
spection Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer declines any liability if
these safety measures are not observed.
The appliance must be connected to a 230 V
50 Hz AC electrical supply.
Before activating the appliance, make sure the
electrical supply voltage is the same as that in-
dicated on the rating plate. The rating plate is
located on the bottom of the appliance.
The appliance is supplied with a 3 core flexible
supply cord requiring a 3 amp plug.
You must obtain and install the plug. The wires
in the mains lead are coloured in accordance
with the following code:
Green and yellow
Blue
Brown
1. Connect the green and yellow (earth) wire
to the terminal in the plug which is marked
with the letter 'E' or the earth symbol
or coloured green and yellow.
2. Connect the blue (neutral) wire to the ter-
minal in the plug which is marked with the
letter 'N' or coloured black.
3. Connect the brown (live) wire to the termi-
nal in the plug which is marked with the let-
ter 'L' or coloured red.
- Earth
- Neutral
- Live
www.zanussi.com
,