Clarke PPH10ND Petunjuk Pengoperasian & Pemeliharaan - Halaman 15
Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian & Pemeliharaan untuk Kompresor Udara Clarke PPH10ND. Clarke PPH10ND 17 halaman. Air compressor
Juga untuk Clarke PPH10ND: Panduan Pengoperasian & Pemeliharaan (10 halaman), Petunjuk Pengoperasian & Pemeliharaan (20 halaman)
Unusual noise from
Bolts loose.
compressor.
Flywheel loose.
Unit installed on an unsuitable
base.
Bearings, piston rings or cylinder
worn.
Valve broken.
Compressor
Insufficient ventilation.
becomes too hot.
Oil level too low (check 2 or 3
times after stopping).
Fault in valves (machine not
stopping).
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Not fully unloading
Non-return valve partly blocked.
Compressor being
overworked and running
continuously.
Tighten bolts.
Tighten flywheel.
Move unit to a more solid base.
Replace worn parts or change
compressor pump.
Change valve parts.
See that sufficient air is supplied to
flywheel or fan of compressor and
that hot air is properly vented.
Fill with oil – see Page 10.
Check, clean/replace.
Check and replace gasket.
Clean cooling fins and suction
filter.
Reset to correct working pressure
detailed on unit.
Check pressure unloading genie,
adjust if necessary, check
valve(s).
Clean or that out non return
valve.
Connect to a supplementary
compressor or install a larger
model.
- 16 -