Aerco AM Series Petunjuk Teknis - Halaman 4

Jelajahi secara online atau unduh pdf Petunjuk Teknis untuk Pemanas Air Aerco AM Series. Aerco AM Series 10 halaman. Gas-fired boilers and water heaters venting application
Juga untuk Aerco AM Series: Manual Aplikasi (8 halaman), Manual Aplikasi (20 halaman)

Aerco AM Series Petunjuk Teknis
AM Series Thermal Insulation Replacement Instruction
5.
Referring to Figure 3, unscrew nut "H." Take note of the gasket between nut "H" and the
gas valve.
Figure 3: Removing the Nut & Spring from the Gas Valve
6.
Disconnect the electrical plug from the gas valve.
7.
Use a screwdriver to remove the spring labeled "A."
8.
Referring to Figure 4, remove the gas valve from its position. Note the O-ring, labeled "L."
07/28/2014
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288
Kit # 62632006
Removing the Burner – Continued
Figure 4: Removing the Gas Valve
TID-0120_0A
Page 4 of 10