Armstrong Air Conditioning 4SCU13LE Series Panduan Petunjuk Pemasangan dan Pemeliharaan - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pemeliharaan untuk Pendingin Udara Armstrong Air Conditioning 4SCU13LE Series. Armstrong Air Conditioning 4SCU13LE Series 20 halaman. Split system air conditioner
Refrigerant Line Sets: Transition from Vertical to Horizontal
Anchored
Heavy Nylon
Wire Tie
Wall
Stud
Metal Sleeve
Refrigerant Line Sets: Installing Vertical Runs (new construction shown)
NOTE: Similar installation practices
should be used if line set is to be
installed on exterior of outside wall.
IMPORTANT:
lines must not
contact structure.
Page 6
Strap Liquid
Line to Vapor
Line
Liquid Line
–
Vapor Line
Wrapped
in Armaflex
Wood Block
Between Studs
Vapor Line Wrapped
with Armaflex
Outside Wall
Refrigerant
PVC Pipe Fiberglass
Automotive
Muffler-Type
Wall
Stud
Metal Sleeve
Figure 8
IMPORTANT: Refrigerant
lines must not contact wall.
Outside Wall
Liquid Line
Caulk
Insulation
Figure 9
Hanger
Liquid Line
–
Vapor Line
Wrapped
in Armaflex
Vapor Line
Strap Liquid
Line to Vapor
Line
Liquid Line
Wire Tie
Inside Wall
Strap
Sleeve
Wire Tie
Wood Block
Wire Tie
Strap
Sleeve
# 48387H005