should be made aware that once a week the hot
water will be warmer following the automatic "weekly
boost". We also therefore strongly recommend the use of a
thermostatic mixing valve (TMV), these blend hot water with
cold water to ensure constant safe shower and bath outlet
temperatures, preventing scalding.
Adjusting and Resetting the Cylinder Thermostat
Adjust the dial to show the desired hot water temperature on
the display, between 25°C to 65°C. The lower the temperature,
the less chance of scalding and the more energy saving. Most
homeowners find a temperature between 48°C-53°C to be
adequate. If the system should overheat, the cause must be
determined and resolved by a suitably qualified person. In the
event of an overheat, the thermostat cuts out automatically.
The reset for the thermostat is under the adjustment dial.
Adjusting the 1 Hour Boost
The ESCTDEB has user defined settings where the duration
of the Legionella Override can be adjusted from 1 to 7 days
or completely disabled to operate as a conventional Dual
Cylinder Thermostat.
1. To disable/adjust the legionella boost turn the unit off
by pressing and holding down the HOLIDAY button
until an audible click is heard and the red LED turns off.
2. Release the button and after approx. 10 seconds press
and hold the HOLIDAY button again. After 5 seconds
the red LED will light up and an audible click is heard,
keep the HOLIDAY button pressed for a further 5
seconds until the LCD display flashes.
3. Release the button and use the HOLIDAY button to
choose between disabling the override (OF) or setting
the delay between the overrides from 1 – 7 days.
9