Section E1 - Rafter Setup (ground post method)
IF YOU DID NOT USE GROUND POSTS, PLEASE PROCEED TO SECTION E2 FOR SETUP.
Step 1: Stand up one of your end rafters. Place the bottom of the rafter into the outside ground
posts and secure with Tek screws through the post into the rafter. Install all of the rafters into
the ground posts at this time. Finish with the other end rafter.
Step 2: When all the rafters are erected, check to make sure they are not corkscrewed. This is
when half of the rafter is leaning toward one end of the shelter and the other half of the same
rafter is leaning toward the opposite end. To correct this, simply push each half rafter in the
direction it needs to go.
Step 3: Insert purlins (horizontal members) into the couplings at the peaks of the rafters and also
at the tops of the legs. Tighten the rafter couplings as you go. Start with the plain end of a 99"
swaged pipe. Continue to add more 99" swaged sections, and end with an unswaged section
that is the correct length so the purlin assembly is the same length as your shelter.
Step 4: Recheck that every rafter is standing up straight (plumb) and that the rafter-to-rafter
distance is 8' when checked at the peak and side couplings.
Step 5: When all rafters appear to be straight, tighten all the couplings.
Step 6: If this is a permanent installation, we recommend that you install a Tek screw at each purlin
joint to secure the connection.
Page 10