Controls & Connectors
MICROPHONE OUT:
DynamicTalk
12V D.C.IN:
GPI: SubD 9 pins female connector to contact close external functions
PIN
1,6
8,9
Only in Conference mode
2
Only in Conference mode
3
Only in Conference mode
4
5
7
NOTE: In conference MODE, if the 2 and 3 pins are not connected to
ground, the upper ring LED is off.
LOWER the microphone
10
XLR connector of the microphone installed in the
XLR4 connector to the power supply
1,2: Ground
3,4: 12Vdc
FUNCTION
Contact close of the customized push button on upper
cover plate (middle button). 100mA Max
Contact close of the TALK push button on upper cover
plate, only in Conference mode.
This function does not work when the device is configured
in PA mode. 100mA Max
Activates the RED LED ring in conference mode,
connecting to GPI ground
Activates the GREEN LED ring in conference mode,
connecting to GPI ground
Connect this pin to GPI ground to RISE the microphone
Connect this pin to GPI ground to LOWER the microphone
GPI ground
Use a PULSE signal to RISE and