ClipperCreek CS EVSE Pedestal Panduan Instalasi - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Rak dan Dudukan ClipperCreek CS EVSE Pedestal. ClipperCreek CS EVSE Pedestal 20 halaman. Electric vehicle supply equipment
IMPORTANT SAFETY INSTRUCTIONS
ClipperCreek Electric Vehicle Supply Equipment (EVSE) is designed with the safety concerns of the end user
as an utmost priority; however, the following safety precautions must be read and followed:
•
The EVSE and electrical wiring should be installed by a qualified electrician in accordance with local
electrical codes and ordinances.
•
Grounding Instructions - The EVSE should be connected to a grounded, metal, permanent wiring
system; or an equipment-grounding conductor should be run with circuit conductors and connected to
a grounding terminal or lead on the EVSE. Connections to the EVSE should comply with all local
electrical codes and ordinances.
•
Call the local service provider anytime a procedural question arises; DO NOT attempt to perform a
procedure you are unsure of.
•
Read all installation instructions carefully before performing the pedestal and EVSE installation.
INSTALLATION REQUIREMENTS
Required.Equipment.for.a.Single-Mount.Pedestal.with.one.EVSE.(One.EVSE.per.Pedestal):
•
One (1) ClipperCreek CS EVSE Pedestal Kit
•
One (1) ClipperCreek CS EVSE
•
One (1) dedicated 208 or 240V AC branch circuit
•
One (1) circuit breaker, appropriately sized with respect to the charging capacity of the EVSE
•
Two (2) Live Line conductors that are appropriately sized based on the EVSE power requirements
with enough length to comfortably pull all the way through and above the top of the pedestal (5 feet of
length is adequate)
•
One (1) Ground Line conductor with enough length to comfortably pull all the way through and above
the top of the pedestal (5 feet of length is adequate)
•
Conduit sized to fit all Live Line and Ground line conductors
•
Four (4) Anchor Bolts with Nuts and Washers
Required.Equipment.for.a.Dual-Mount.Pedestal.with.two.EVSE.(Two.EVSE.per.Pedestal):
•
One (1) ClipperCreek CS EVSE Pedestal Kit
•
One (1) ClipperCreek CS Dual-Mount Pedestal Kit
•
Two (2) ClipperCreek CS EVSE
•
Two (2) dedicated 208 or 240V AC branch circuits
•
Two (2) circuit breakers, appropriately sized with respect to the charging capacity of each EVSE
•
Two pairs (2x2) Live Line conductors (one pair for each EVSE) that are appropriately sized based on the
EVSE power requirements with enough length to comfortably pull all the way through and above the
top of the pedestal (5 feet of length is adequate)
•
Two (2) Ground Line conductors (one for each EVSE) with enough length to comfortably pull all the
way through and above the top of the pedestal or a single bonded Ground Line
•
Conduit sized to fit all Live Line and Ground Line conductors
•
Four (4) Anchor Bolts with Nuts and Washers
Refer to the EVSE documentation to determine the appropriate circuit breaker current capacity.
1
All conductors must be appropriately sized for the EVSE current capacity, in accordance with local and NEC electrical codes.
2
2
CS EVSE PEDESTAL INSTALLATION GUIDE
2
Page 5
ClipperCreek
1
1
2
, Inc.