Cypress EZ-PD CY4533 Manual - Halaman 17
Jelajahi secara online atau unduh pdf Manual untuk Motherboard Cypress EZ-PD CY4533. Cypress EZ-PD CY4533 20 halaman. Barrel connector replacement (bcr) evaluation kit
Figure 3-2. Complete Setup: Amazon Echo, CY4533 EVK with Barrel Plug Cable, and Apple 30W USB-C Power Adapter
3.2.2 Demo #2: Test with a Multimeter and EZ-PD Protocol Analyzer
In this demo, a multimeter is connected to the CY4533 EVK to test the various voltages offered by the USB Type-C power
adapter (or Power Bank). You can also connect an electronic load in parallel with the multimeter to test current capabilities
of the power adapter (or power bank) and the CY4533 EVK.
In addition, you will use the CY4500 EZ-PD
between BCR and the power adapter.
Figure 3-3. CY4533 EVK, Multimeter, and a Type-C Power Adapter (Apple 30 W USB-C Adapter)
TYPE-C POWER
ADAPTER
To set up the demo, do the following:
1.
Connect a multimeter to the DC_OUT terminal block J3. If desired, you may also have a load connected in parallel
with the multimeter. See Board Details to determine the polarity of the terminal block or look at the markings on the
back of the board.
Connect the CY4533 EVK to the EZ-PD Protocol Analyzer's plug. Connect the analyzer to your PC using the supplied
2.
USB Micro-B cable.
3.
Ensure that the analyzer software and the necessary drivers are installed. See CY4500 EZ-PD Protocol Analyzer's
website
for details.
CY4533 EZ-PD™ BCR Evaluation Kit Guide, Document Number: 002-25263 Rev. *B
Protocol Analyzer
Connect to a PC
CY4500
USB-C CABLE
EZ-PD Analyzer
to analyze the USB Power Delivery packets exchanged
CY4533 EVK
BCR
2 3 4
1
5
DC_OUT
Kit Operation
5.10V
V A
A
V GND
17