SPECIFICATIONS
Power Source
Output
Maximum No. of Applicators per Pumping Unit
Maximum No. of Applicators operating simultaneously
Maximum Length of Distribution Tubing
Typical Chemical Consumption per Applicator (Foam)
Typical Chemical Consumption per Applicator (Dip)
Operating Temperature
PROBLEMS & FAULT FINDING
Problem
No foam (or Dip) produced
in cup when gun trigger
squeezed (ALL units)
No foam (or Dip) produced
in cup when gun trigger
squeezed (at ONE unit
only)
– Air – Farm Compressor
– Operating Pressure
– Air
Likely Cause
No Air Supply present
Air supply not
reaching applicator.
• 8 Litres/minute minimum
• 3 - 4 psi (0.2 - 0.28 bar) Max.
• 5 – 8 L/min at 3 - 4 psi (0.28
• 10
• 2
• 45 Metres
• 3 - 4 mL/second
• 10 -15 mL/second
• 5 – 40 °C
Probable Solution
Switch On Mains electricity supply to
compressor and check that tap at regulator
in ON position.
Observe the Pressure Gauge of regulator.
Disconnect the distribution tube at the outlet
of the Regulator. If plenty of air exits from
fitting then it is probable that the distribution
tubing is blocked, or restricted by over-tight
cable ties.
Check for leaking connections on
distribution tubing system.
Leaking connections, or blocked tubing –
check and remedy.
Trigger valve stuck or blocked – check valve
and lubricate with silicone aerosol.
Foaming cup dirty or blocked – clean to
remove dirt from gauzes, or replace with
new cup.
-5-
Bar max.)