Ambifuego KALIDO 73 Petunjuk Pemasangan, Pengguna, dan Servis - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Pemasangan, Pengguna, dan Servis untuk Perapian Dalam Ruangan Ambifuego KALIDO 73. Ambifuego KALIDO 73 15 halaman. Convector gas fire
No restrictor plate or flue damper is permitted. Where a variable damper is fitted, this
must be removed.
c)
A dedicated power flue kit is available for the appliance. The appropriate fitting
instructions are supplied with the kit.
7
Ventilation.
Purpose made ventilation must be installed in accordance with local regulations.
8
The appliance is designed for use with both natural gas and propane. The two gases
require different burners that are not interchangeable between the different gas types.
9
The appliance must not be installed in a room containing a bath or shower or in a private
garage.
10
Shelf
If a shelf made of combustible material is to be fixed to the wall above the appliance a
space of at least 150mm must be left between the top of the fascia and the underside of
the shelf.
Fitting the Firebox
1 Check that the fireplace is of the correct size or has been modified to accept the selected
firebox. (See Figure 1)
2
It is recommended that, before proceeding further, a simple smoke test be performed to
check the condition of the chimney. Light a smoke match or a twist of rolled paper, hold
it under the open flue and observe the behaviour of the smoke. If it is being drawn into
the chimney proceed with the installation. If not, pre-heat the chimney over the period of
a few minutes and recheck. If there is any doubt about the soundness of the chimney a
smoke pellet should be used after preheating the flue and if smoke still fails to clear,
further investigation of the chimney is required and the appliance MUST NOT be fitted
until any fault has been rectified.
3
Clear the recess of any loose material and ensure that the base on which the appliance
will stand is level.
4
Make good the plasterwork or wall decoration up to the edges of the fire opening.
5
Disassemble the appliance in order to separate the flue connector from the convector
box so that it can be connected to the chimney.
5
.