a
Remove the glass window by undoing the two nuts + two screws and lifting clear.
Store it in a safe place.
b
Remove the screw at the bottom of the fascia and pull the burner forward.
Remove the four screws holding the control fascia in position. Remove the screw
holding the circulation fan switch plate to the gas control valve. Loosen the
thermocouple nut and remove the connection wires from the flue temperature
switch. Lift the burner assembly clear of the appliance.
c
Undo the four screws holding the firebox in the convector box and lift the firebox
out of the convector box. See figure 2. As the firebox is lifted away disconnect the
circulation fan lead from the wiring box by separating the 'Molex' connectors.
d
Unscrew the ten self tapping screws securing the flue break assembly to the
convector box and remove.
e
From inside the convector box loosen the four screws holding flue connector, slide
it sideways and remove from the outside of the convector box.
6
Install the register plate and the connecting length of flue pipe or line the chimney with
100mm flexible flue liner. Connect and seal the lower end of the flue pipe or liner to the
flue connector. Temporarily lodge the flue connector in position until the convector box is
placed in position. Alternatively a gas flue can be used in which case the appropriate
appliance connector will have to be selected.
7
The gas supply should be routed from the meter or cylinder to a point at the rear of the
fireplace. This point should be on the centre line of the appliance and 35mm above the
base on which the convector box will sit. From this point route the supply in 8mm
diameter tubing forward to the front of the fire opening. Exposed pipe within the fire
opening should be wrapped, painted with bituminous paint or factory sheathed.
'Knock out' the gas entry hole in the rear of the convector box with a sharp hammer blow.
8
Place a diaphragm grommet (supplied) in the hole and cut a slit for the gas supply pipe.
Slide the convector box into position. Reach up through the flue aperture and draw the
flue connector down into position. Pull the four screws previously loosened through the
keyhole slots, slide sideways and tighten the four screws. Re-assemble the flue break
assembly into the convector box with the ten self tapping screws previously removed.
Make sure the convector box is pushed fully home and then fix the flanges to the wall
with wall plugs and screws. Make sure the flue temperature switch sensor is still in
position in its bracket.
9
Place the heat exchanger in position in front of the flue assembly within the convector
box making sure that the flue spigot on the back of the firebox is inserted into the
rectangular hole in the flue break. Re-connect the power supply to the fan using the
FIG. 3
6