Sfoglia online o scarica il pdf Manuale di istruzioni e ripartizione delle parti per Utensile elettrico AME 24820. AME 24820 18. Automatic tire inflator 3 modes in one

4.0

Troubleshooting

The following chart has been prepared to assist with diagnosis of faults
PROBLEM
No display.
The inflation process does not
commence, even when the
pressure is set and the hose is
connected to the tire.
The display will not move or is
stuck on a particular value.
The unit deflates very slowly.
The unit no longer beeps.
The inflation process
commences but does not
complete.
ER1
ER2
ER3
ER4
ER5
AME INTERNATIONAL
INSTRUCTION MANUAL
& PARTS BREAKDOWN
POSSIBLE CAUSE
No power supply
The tire is deflated below 3
psi, 20 kPa or 0.2 bar.
The hose connector is faulty.
The faceplate/switch is
damaged.
The silencer plug on the valve
block is blocked.
The beeper is damaged.
Low or nil supply pressure.
Unstable pressure, faulty hose
connector.
Unstable pressure, faulty hose
connector.
Incorrect supply pressure.
Inflate & Deflate valve
connections are reversed.
Low or nil supply pressure.
Initial or final pressure is too
high, exceeding the maximum
pressure by more than 20 psi,
140 kPa or 1.4 bar.
Low voltage supply.
- 9 -
SOLUTION
Check power supply
Press
Replace the hose
Connector.
Replace the faceplate/
switch.
Remove and clean the
silencer plug.
Replace the beeper.
Check the air compressor
supply pressure.
Replace the hose
connector.
Replace the hose
connector.
Check the air compressor
supply pressure.
Check the valve
connections on the PCB.
Check the air compressor
supply pressure.
Disconnect hose
connector, reset
processor by switching off
the power for a minimum
of 5 sec. If error
message reappears
replace PCB.
Check power supply. The
message will clear when
the correct voltage is
restored.