Troubleshooting, cont.
The following chart has been prepared to assist with diagnosis of faults
PROBLEM
POSSIBLE CAUSE
ER6
Programme or PCB Error
ER8
Calibration Error
ER9
Automatic Calibration Check/
Calibration Error
ERP
Unstable supply pressure
Hose disconnection during inflate cycle Check hose connection.
ERU
Short circuitry on valve connection
ERB
Short circuitry on buzzer connection
AME INTERNATIONAL
INSTRUCTION MANUAL
& PARTS BREAKDOWN
- 10 -
SOLUTION
Reset machine by switching off
power for 5 seconds. If error
message reappears replace PCB.
Unit requires calibration,
contact your local distributor
or service agent.
Disconnect hose connector, reset
machine by switching off power
for 5 seconds. The ER9 message
will clear automatically when the
factory calibration is restored.
If the ER9 message continues to
reappear, replace the PCB.
Check the supply pressure.
Check and dry up the valve connection.