If you substitute swimming pool chlorine (10% – 15% sodium
hypochlorite) you would need about half as much.
The suggested method on fill and start-up would be to use sodium
dichlor on the initial application of the sanitizer and then the first time
you need to adjust the free chlorine. Any subsequent time the free
chlorine needs to be adjusted use 0.63 OZ (1.25 tablespoons) of
regular household bleach (6% sodium hypochlorite). The reason for
this is that the sodium dichlor contains cyanuric acid (CYA) as a
stabilizing agent. The CYA keeps the chlorine from degrading. If you
continue to use soduim dichlor to raise the free chlorine, over time the
CYA builds up in the water and makes the chlorine ineffective. The
initial application of sodium dichlor will have enough CYA to stabilize
the chlorine for the long run. This method will minimize maintenance
and save you money! The easy formula is first and second application
is sodium dichlor and all others bleach.
Aero-Spa™ not running
1. Reset GFCI breaker. If this problem persists replace GFCI
breaker
2. Reset circuit breaker at house fuse panel. If this problem
persists call Aero-Spa™, LLC
3. Bypass timer, if this corrects the problem replace timer
4. If these steps do not solve the problem call Aero-Spa™, LLC
Water is cloudy
1. Increase the run time cycle
2. Repeat step 1 until water clarity improves
3. If these steps do not solve the problem call Aero-Spa™, LLC
No bubbles coming from sintered diffuser
1. Verify Aero-Spa™ is running
2. Verify ozone tube is not broken
3. Verify ozone tube is not pinched or disconnected
4. If these steps do not solve the problem call Aero-Spa™, LLC
Strong ozone odor near Aero-Spa™
1. Verify ozone tube is not broken
2. Verify ozone tube is not pinched or disconnected
3. Turn off air pump and call Aero-Spa™, LLC

TROUBLESHOOTING

© Copyright Aero-Spa®, LLC 2013 P/N102203 rev G
9