Determination of a start time:
When the air conditioner is switched off, press the TIMER button to select the desired start time. (A value
between 1 - 24 hours can be selected). After this selected time has elapsed, the unit switches on
automatically (with the last used settings).
7. Activation of night mode (low-noise operation)
Press the SLEEP button and the silent night mode is activated.
The activated night mode automatically increases the target temperature by 1°C in the first hour. In the second
hour, the target temperature is automatically increased by another 1 °C. After that, the target temperature is kept at
this level.
Furthermore, the night mode always uses the weak operating strength (L).
Pressing the SLEEP key again cancels the silent night mode and reactivates the last selected settings.
Note: After 12 hours of operation in night mode, the air conditioner switches off automatically. In addition, night
mode cannot be activated in the following operating modes: Automatic mode, Fan mode or Dehumidification mode.
8. Remote control
All functions and settings as described in points 1 - 7 above can also be
operated/adjusted with the remote control supplied.
The remote control requires two AAA batteries (not included).
9. Error display
The air conditioner detects malfunctions and displays them in the unit's display panel.
If the display field shows "E1" or "E2", please contact your dealer.
10. Other operating instructions
10.1.
To ensure a long service life of the compressor, please do not switch the unit off and on again within 3
minutes (switching the unit off and then on again shortly afterwards will damage the compressor).
10.2.
The cooling circuit (compressor) switches off as soon as the ambient air is below the target temperature.
However, the air circulation continues. If the ambient air rises above the target temperature, the cooling
circuit (compressor) also switches on again automatically.
11. Operating instructions regarding refrigerant R290
Read these instructions carefully !
This air conditioner operates with the refrigerant R290, which is highly flammable and explosive.
Therefore, please take special care that the copper lines are not damaged at any time!
The appliance should not be placed in a room where other appliances are operated at the same time
which have an electric heater or an open flame.
Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an
emerging odour !
Make sure that the outlet of the exhaust air is always given and not obstructed by other objects !
Only appropriately trained specialists are permitted to carry out repairs to the cooling lines and the
compressor! Always contact a specialist in case of a problem !