American Standard Innsbrook Lavatory Faucet M968498 Manuale di istruzioni per l'installazione - Pagina 10

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Arredamento per interni American Standard Innsbrook Lavatory Faucet M968498. American Standard Innsbrook Lavatory Faucet M968498 12. Innsbrook lavatory faucet with selectronic technology

American Standard Innsbrook Lavatory Faucet M968498 Manuale di istruzioni per l'installazione
FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted
by pause, replace battery, or call 1800-442-1902.
Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but
turns off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to -
& Red to + is correct.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.
9