American Standard Innsbrook Lavatory Faucet M968498 Manual de instruções de instalação - Página 10
Procurar online ou descarregar pdf Manual de instruções de instalação para Mobiliário de interior American Standard Innsbrook Lavatory Faucet M968498. American Standard Innsbrook Lavatory Faucet M968498 12 páginas. Innsbrook lavatory faucet with selectronic technology
FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted
by pause, replace battery, or call 1800-442-1902.
Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but
turns off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to -
& Red to + is correct.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.
9