FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted
by pause, replace battery, or call 1800-442-1902.
Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but
turns off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to -
& Red to + is correct.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.