Amerlux GRUV - 1.5 - GB-LED Manuale di istruzioni per l'installazione - Pagina 3
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Apparecchiature di illuminazione Amerlux GRUV - 1.5 - GB-LED. Amerlux GRUV - 1.5 - GB-LED 6.
AMERLUX
LIGHTING SOLUTIONS
GRUV - 1.5 - GB-LED WALL MOUNTED INSTALLATION (HORIZONTAL/VERTICAL)
Gyp Board
WARNING - RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN
ONLY. FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL
AND FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING .
Mounting Points
6.00"
Individual Installation -
*: Fixture MUST be mounted before wall is installed.
1. Install BLOCKING as shown by
others. Secure housing to blocking
using Self-drilling screws (supplied by
others) thru Fixture Flange.
2. Once the fixture is secure, feed
power source through the knock-out.
Splice to harness according to code.
3. * Install wall (By Others)
4. Spackle in fixture.
5. Snap-in LENS.
Amerlux, LLC. - 178 Bauer Drive, Oakland NJ 07436 - T: 973-882-5010 - F: 973-882-2605
R
ADAPT. ABILITY.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
6.00"
X
Example of a continuous row
BLOCKING
SUPPORT METHOD
(SUPPLIED BY OTHERS)
Ceiling contractor
to spackle, feather
and sand at ceiling
interface.
ACCESS PLATE DETAIL
WIRING CONNECTION
0-10V DIM shown. For non-DIM applications
cap Purple (+) and Gray (-). Wire nuts
.
supplied by others
INSTALLATION INSTRUCTIONS
TM
SHEET #:
689-0512 (3 of 5)
X
12.00"
Remove 7/8" KO in access
cover at power feed location.
www.amerlux.com
SPEC. SHEET
REFERENCE:
6.00"
X
6.00"
BLOCKING
REQUIRED
(BY OTHERS)
SNAP IN LENS