Ames Instruments 57716 Manuale d'uso e istruzioni di sicurezza - Pagina 6

Sfoglia online o scarica il pdf Manuale d'uso e istruzioni di sicurezza per Strumenti di misura Ames Instruments 57716. Ames Instruments 57716 8. Professional ac line splitter

Ames Instruments 57716 Manuale d'uso e istruzioni di sicurezza
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section
at the beginning of this manual including all text under
subheadings therein before set up or use of this product.
Electrical shock can cause death or injury! NEVER TOUCH
exposed conductors of
General Operating Instructions
1.
Connect the Power Input Plug
into a grounded 120VAC outlet.
2.
Devices with standard
AC plugs can be tested:
Standard AC Plugs
To test the working current
3.
of the connected device:
a. Turn the device's power switch
to OFF and connect it to the
Input Socket of the AC Line Splitter.
b. Set Clamp Meter (sold separately)
to read AMPS and clamp it around
the X1 (normal current load)
or X10 (ten times the normal
current load) test terminal.
Note: When using x10 position,
divide reading on Clamp Meter by
10 to obtain correct reading.
AC Line Splitter
Power cord from
device under test
Page 6
electricity.
120VAC Outlets
Clamp Meter
For technical questions, please call 1-888-866-5797.
c. Power on the device and read
the result on the Clamp Meter.
d. When finished, turn the device's
power switch OFF and then
remove the Clamp Meter.
e. Unplug the device and then
unplug the AC Line Splitter.
To test the voltage of the
4.
connected device:
a. Set multimeter (sold separately)
to read AC VOLTS, and
then plug it's test leads into
the AC Voltage Test Jacks
on the AC Line Splitter.
b. Turn the device's power switch
to OFF and connect it to the
Input Socket of the AC Line Splitter.
c. Power on the device and read
the result on the multimeter.
d. When finished turn the device's
power switch OFF and remove
it from the AC Line Splitter.
e. Unplug the AC Line Splitter
and then remove the
multimeter's test leads.
5.
When finished, unplug the
AC Line Splitter and store indoors
out of children's reach.
Note: To calculate power
(wattage) of the connected device,
multiply voltage by current.
Power = voltage x current
Item 57716