Baumer GIM500R Manuale - Pagina 7
Sfoglia online o scarica il pdf Manuale per Accessories Baumer GIM500R. Baumer GIM500R 20. Inclination sensors
Anche per Baumer GIM500R: Manuale (29 pagine), Manuale (13 pagine), Istruzioni per il montaggio (2 pagine)
Output signals
3.3
Analog output signals
3.3.1
Within the sensing range, the output signals come as analog values from minimum to maximum. According
to the product variant, the analog signal is current or voltage dependent.
Outside the sensing range, the output value jumps from the maximum to the minimum signal value at half
the rotation angle (α) (see diagram below). When the sensor is inclined in the opposite direction the value
jumps from the minimum to the maximum signal value.
Signal
max
min
Overview of output signals
Analog
Output
Interface
Underrange
0...5 V
0 V
0...10 V
0 V
4...20 mA
4 mA
0...20 mA
0 mA
0...24 mA
0 mA
0.5...4.5 V
0.5 V
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
α
α/2
Output
Overrange
5 V
10 V
20 mA
20 mA
24 mA
5.5 V
Inclination
7/20
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany