Baumer GIM500R 매뉴얼 - 페이지 7
{카테고리_이름} Baumer GIM500R에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer GIM500R 20 페이지. Inclination sensors
Baumer GIM500R에 대해서도 마찬가지입니다: 매뉴얼 (29 페이지), 매뉴얼 (13 페이지), 조립 지침 (2 페이지)
Output signals
3.3
Analog output signals
3.3.1
Within the sensing range, the output signals come as analog values from minimum to maximum. According
to the product variant, the analog signal is current or voltage dependent.
Outside the sensing range, the output value jumps from the maximum to the minimum signal value at half
the rotation angle (α) (see diagram below). When the sensor is inclined in the opposite direction the value
jumps from the minimum to the maximum signal value.
Signal
max
min
Overview of output signals
Analog
Output
Interface
Underrange
0...5 V
0 V
0...10 V
0 V
4...20 mA
4 mA
0...20 mA
0 mA
0...24 mA
0 mA
0.5...4.5 V
0.5 V
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
α
α/2
Output
Overrange
5 V
10 V
20 mA
20 mA
24 mA
5.5 V
Inclination
7/20
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany