Baumer GIM500R Manuale - Pagina 29
Sfoglia online o scarica il pdf Manuale per Sensori di sicurezza Baumer GIM500R. Baumer GIM500R 29. Inclination sensors
Anche per Baumer GIM500R: Manuale (20 pagine), Manuale (13 pagine), Istruzioni per il montaggio (2 pagine)
4
Terminal assignment
M12 flange connector, 5-pin
4.1
Pin
Assignment
1
CAN_GND
2
+Vs
3
GND
4
CAN_H
5
CAN_L
2xM12 flange connector, 5-pin
4.2
Pin
Assignment
1
CAN_GND
2
+Vs
3
GND
4
CAN_H
5
CAN_L
Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps Vs-Vs and GND-GND is 1 A each.
Cable
4.3
Core color
Assignment
White
+Vs
Brown
GND
Green
n.c.
Yellow
n.c.
Grey
n.c.
Pink
CAN_H
Blue
CAN_L
Red
CAN_GND
Baumer_GIM500R_CANopen_MA_EN.docx
03.19
Description
Ground connection relating to CAN
Voltage supply
Ground connection relating to +Vs
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
Description
Ground connection relating to CAN
Voltage supply
Ground connection relating to +Vs
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
Description
Voltage supply
Ground connection relating to +Vs
-
-
-
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
Ground connection relating to CAN
29/29
M12 (male)
M12 (male/female)
www.baumer.com